beautypg.com

Zanussi ZWF 14069W User Manual

Page 19

background image

Open the porthole and re-

move the polystyrene

block fitted on the door

seal.

Fill the smaller upper hole

and the two large ones

with the corresponding

plastic plug caps supplied

in the bag containing the

instruction booklet.

Positioning

Install the machine on a flat hard floor. Make sure that air

circulation around the machine is not impeded by carpets,

rugs etc. Check that the machine does not touch the wall

or other kitchen units. Level the washing machine by

raising or lowering the feet. The feet may be tight to adjust

as they incorporate a self locking nut, but the machine

MUST be level and stable.

Any necessary adjustment can be made with a spanner.

Accurate levelling prevents vibration, noise and displace-

ment of the machine during operation. Never place card-

board, wood or similar materials under the machine to

compensate for any unevenness in the floor.

If necessary, check the

setting with a spirit level.

Water inlet

Warning! This appliance must be connected to a

cold water supply
Caution! Before connecting up the appliance to new

pipework or to pipework that has not been used for

some time, run off a reasonable amount of water to flush

out any debris that may have collected

Caution! Do not use the hose from your previous

appliance to connect to water supply.

The inlet hose is screwed to the back of the appliance.

Connect the hose to a tap

with a 3/4” thread. Always

use the hose supplied with

the appliance.

35°

45°

The other end of the inlet hose which connects to the

appliance can be turned as showed in the picture.

Do not place the inlet hose downwards. Angle the hose

to the left or right depending on the position of your

water tap. Set the hose correctly by loosening the ring

nut. After positioning the inlet hose, be sure to tighten

the ring nut again to prevent leaks.

Caution! The inlet hose must not be lengthened. If

it is too short and you do not wish to move the tap,

you will have to purchase a new, longer hose specially

designed for this type of use.

Warning! Installation should comply with local

water authority and building regulations’

requirements.

The appliance must be connected to a cold water supply.

A minimum water pressure of 0.05 MPa (0.5 bar) is

required for safe operation of the appliance.

If you cannot make the cold water connection direct from

the rising mains, you may be able to operate the appliance

from your cold water storage system.

There should be a minimum vertical distance of 5.02 m

(16.5 ft) between the appliance’s inlet and the bottom of

the water storage tank.

Water drainage

This appliance is designed to be permanently plumbed

into your home's drainage system using one of the fol-

lowing methods.

1. Into a drainage standpipe.

19