Appendix – Z Microsystems SL User Manual
Page 38

Doc# 27-0032UM Rev A Issued 07/05
38
* Results of Environmental Tests pending
** Unit will power up and is legible at -20°C; backlight life is reduced
Non-Op Temp
-40° to 70° C
Humidity
5%-95% Non-Condensing
Operating Altitude
Up to 10,000 ft
Non-Op Altitude
Up to 40,000 ft
Vibration
MIL-STD-167
Shock
MIL-STD 810E (Method 516) 30 g’s
MIL-S-901D (in isolated rack)
Sand and Dust
5.5 MPH for 25 mins (display bezel, keyboard and
trackball only)
Drip
MIL-STD-810E (display bezel, keyboard and
trackball only)
Fungus
Non-Nutrients/Contaminants
Reliability
MTBF
Display: 20,000 hrs w/ backlight change at 10,000
hrs.
MRRT
<30 minutes
Safety
UL 1950 (used as a design guideline)
EMI
MIL-STD-461E, RE101 (Army Limits), RE102
(Navy Fixed Limits), RS101, RS103, (20v/m 2MHz
and 60v/m 1GHz-18GHz, CE101, CS114, CS115,
CS116
Quality/Workmanship
IPC/ISO 9001:2000 and applicable section of
MIL-HDBK-454
APPENDIX