Too much ice has formed
Is the lid not closed completely? Check for obstructions.
Is the water drainage plug correctly positioned?
The lid will not close completely
Is there excessive frost or a package preventing the lid from closing?
Is the valve blocked?
Are food packages blocking the lid?
Is the lid seal dirty or sticky?
Does the freezer wobble or seem unstable?
The lid is difficult to open
Is the lid seal dirty or sticky?
Is the valve blocked?
If you still need help, please contact your local Service Force Centre.
Service or repair
In cases of breakdown or faults, your freezer must be serviced by an authorized Electrolux Service engineer.
Important! Under no circumstances should you attempt to repair the appliance yourself.
Technical Data
Climatic classification
Ambient temperature limits
SN
from +10°C to +32°C
N
from +16°C to +32°C
ST
from +18°C to +38°C
T
from +18°C to +43°C
This appliance complies with the following EC Directives:
73/23/EEC of 19. 02. 1973 Low-Voltage Directive
89/336/EEC of 03. 05. 1989 (including Amendment Directive 92/31/EEC - EMC
Directive)
Model
BMI230
BMI265
ZFC622WA ZFC626WA
Volume (gross)
Litre
221
261
Volume (net)
Litre
216
255
Height
cm
87,6
87,6
Width
cm
105
119
Depth
cm
66,5
66,5
Weight net
kg
50
57
Energy consumption
24 Stunden
kWh/24 h
0,599
0,649
Freezing capacity
kg/24 h
24
27
Hold-over time
Hours
48
50
Rated power
Watt
80
90
Voltage
Volts
230
230
Climatic class
SN/N/ST
SN/N/ST