Troubleshooting, Troubleshooting procedures for milano island – Zephyr ZML-M90AG/AS User Manual
Page 19
T
roubleshooting
17
TROUBLESHOOTING PROCEDURES FOR MILANO ISLAND
Issue
Cause
What to do
After installation,
the unit doesn’t
work.
1. The power source is not turned ON.
1. Make sure the circuit breaker and the unit’s
power is ON.
2. The power line and the cable locking connector
is not connecting properly.
2. Check the power connection with the unit is
connected properly.
3. The switch board and control board wirings are
disconnected.
3. Make sure the wirings between the switch
board and control board are connected
properly.
4. The switch board or control board is defective.
4. Change the switch board or control board.
Light works,
but motor is not
turning.
1. The motor is defective, possibly seized.
1. Change the motor.
2. The thermally protected system detects if the
motor is too hot to operate and shuts the motor
down.
2. The motor will function properly after the
thermally protected system cool down.
3. Damaged capacitor.
3. Change the capacitor.
4. The switch board or control board is defective.
4. Change defective part.
The unit is
vibrating.
1. The motor is not secure in place.
1. Tighten the motor in place.
2. Damaged blower wheel.
2. Replace the blower.
3. The hood is not secured in place.
3. Check the installation of the hood.
4. The switch board or control board is defective.
4. Change defective part.
The motor is
working, but the
lights are not.
1. Defective halogen bulb.
1. Change the halogen bulb.
2. The light bulb is loose.
2. Tighten the light bulb.
The hood is
not venting out
properly.
1. The hood might be hanging to high from the
cook top.
1. Adjust the distance between the cook top and
the bottom of the hood within 28” and 36”
range.
2. The wind from the opened windows or opened
doors in the surrounding area are affecting the
ventilation of the hood.
2. Close all the windows and doors to eliminate
the outside wind fl ow.
3. Blockage in the duct opening or ductwork.
3. Remove all the blocking from the duct work or
duct opening.
4. The direction of duct opening is against the wind.
4. Adjust the duct opening direction.
5. Using the wrong size of ducting.
5. Change the ducting to at least 6” or higher
for the internal blower and 8” or higher for the
external blower.
Metal Filter is
vibrating.
1. Metal
fi lter is loose.
1. Change the metal fi lter.
- ZML-E42AG/AS 24 Inch Microwave Drawer Warranty ZVO-M90AG ZVO-E30AG ZSA-E30BS290 ZSAE30BS ZSA-M90BB ZSAM90BS ZSA-E30BB ZSA-M90BS290 ZMI-M90AS ZMIM90AG AK8100AS ZGE-E30AS ZGE-E36AS290 ZGE-E36AS ZGE-E30AS290 AK8200AS AK8300ASX GU5/MR16 TYPHOON AK2148 TYPHOON AK2136 TYPHOON AK2142 TYPHOON AK2100 ZRM-E36AS ZRM-E42AS