Error messages, Digital out a/b pin assignment table, Led level meter – Yamaha AD8HR AD User Manual
Page 15
14
Appendix
■ LED Level Meter
Error Messages
The AD8HR automatically diagnoses itself at the time of power up. If it detects a system abnormality,
one of the following error messages appears. If an abnormality is detected, consult your Yamaha dealer.
E1:
The backup battery voltage is low. If the voltage is lowered further, the stored data will be erased. Ask
your dealer to replace the battery.
E2:
The backup memory is corrupted.
E3:
The backup battery voltage is very low and the backup memory is corrupted.
DIGITAL OUT A/B Pin Assignment Table
Input
Output
Conditions
MIN
TYP
MAX
UNITS
INPUT 1–8
DIGITAL OUT 1–8
OVER red LED: ON
0
dBFs
–6 amber LED: ON
–6
dBFs
–12 amber LED: ON
–12
dBFs
–18 amber LED: ON
–18
dBFs
–30 green LED: ON
–30
dBFs
–48 green LED: ON
–48
dBFs
Parameter
Conditions
MIN
TYP
MAX
UNITS
Sampling
Frequency
Frequency Range
Normal Rate
39.69
50.88
kHz
Double Rate
79.38
101.76
kHz
Jitter of PLL
DIGITAL IN fs=44.1kHz
10
ns
DIGITAL IN fs=48 kHz
10
ns
DIGITAL IN fs=39.69–50.88 kHz
20
ns
DIGITAL IN fs=88.2 kHz
10
ns
DIGITAL IN fs=96 kHz
10
ns
DIGITAL IN fs=79.38–101.76 kHz
20
ns
Internal
Clock
Frequency
word clock : int 44.1 kHz
44.1
kHz
word clock : int 48 kHz
48
kHz
word clock : int 88.2 kHz
88.2
kHz
word clock : int 96 kHz
96
kHz
Accuracy
word clock : int 44.1 kHz
50
ppm
word clock : int 48 kHz
50
ppm
word clock : int 88.2 kHz
50
ppm
word clock : int 96 kHz
50
ppm
Jitter
word clock : int 44.1 kHz
5
ns
word clock : int 48 kHz
5
ns
word clock : int 88.2 kHz
5
ns
word clock : int 96 kHz
5
ns
Signal Delay
analog input to digital output
@fs=48 kHz
0.9
ms
@fs=96 kHz
0.45
ms
Signal
Data In Ch
*1
*1. Data In Ch can be received only on DIGITAL OUT A.
Data Out Ch
Open
GND
1–2
1–2
3–4
5–6
7–8
Pin
Hot
1
5
6
7
8
2, 3, 4, 9,11,
15, 16, 17
10, 12, 13,
22, 23, 24, 25
Cold
14
18
19
20
21
25
14
13