beautypg.com

Installation – Zanussi ZFC 321 WB User Manual

Page 9

background image

Installation

Positioning

Warning! If you are discarding an old appliance that

has a lock or catch on the lid, you must ensure that

it is made unusable to prevent young children being

trapped inside.
Important! The appliance shall have the plug accessible

after installation.
This appliance can be installed in a garage or cellar, but

for optimum performance install this appliance at a loca-

tion where the ambient temperature corresponds to the

climate class indicated on the rating plate of the appliance:

Climate

class

Ambient temperature

SN

+10°C to + 32°C

N

+16°C to + 32°C

ST

+16°C to + 38°C

T

+16°C to + 43°C

Electrical Connection

Caution! Any electrical work required to install this

appliance should be carried out by a qualified

electrician or competent person.

Warning! This appliance must be earthed.

The manufacturer declines any liability should these

safety measures not be observed.

1

2

3
4
5

Important! The wires in the mains lead are coloured in

accordance with the following code:

1

Green and Yellow:

Earth

3

Brown:

Live

5

Blue:

Neutral

As the colours of the wires in the mains lead of this ap-

pliance may not correspond with the coloured markings

identifying the terminals in your plug, proceed as follows:
1. Connect the wire coloured green and yellow to the

terminal marked either with the letter “E“ or by the
earth symbol or coloured green and yellow.

2. Connect the wire coloured blue to the terminal either

marked with the letter “N“ or coloured black.

3. Connect the wire coloured brown to the terminal ei-

ther marked with the “L“ or coloured red.

4. Check that no cut, or stray strands of wire is present

and the cord clamp

4

is secure over the outer

sheath.

5. Make sure the electricity supply voltage is the same

as that indicated on the appliance rating plate.

6. Switch on the appliance.
The appliance is supplied with a 13 amp plug fitted

2

.

In the event of having to change the fuse in the plug sup-

plied, a 13 amp ASTA approved (BS 1362) fuse must be

used.

9