beautypg.com

Storing your yard vacuum – Yard-Man 24A-061I401 User Manual

Page 12

background image

12

Figure 14

Remove lock nut that secures flail screen to the
lower housing. The flail screen does not have to be
removed. Refer to Figure 11.

Remove the hex bolt, lock washer, and flat washer
that secure the impeller assembly to the crankshaft.
See Figure 15.

Figure 15

Apply lubricant to the threads of impeller removal
tool and then thread the tool into the crankshaft.
Stop when the impeller assembly can move on the
crankshaft.

Remove the impeller assembly from the crankshaft.
Unthread the impeller removal tool from the
impeller assembly.

Remove the blade using a 3/16” allen wrench on
the outside of the blade and 1/2” wrench on the
impeller assembly.

Replace or sharpen chipper blade.

When sharpening blade, protect hands by using
gloves and follow the original angle of grind.

Reassemble by performing the previous steps in
reverse order.

Tighten blade screws to 210-250 in-lbs.
Tighten impeller bolt to 375-425 in-lbs.

NOTE: Make certain chipper blade is reassembled with
the sharp edge facing upward. See Figure 16.

Figure 16

Storing Your Yard Vacuum

Clean the equipment thoroughly.

Wipe equipment with a oiled rag to prevent rust.

Refer to engine manual for correct engine storage
instructions.

Store unit in a clean, dry area. Do not store next to
corrosive materials such as fertilizer.

Nozzle
Screws

Lower Housing
Screws

Housing
Screws

Upper
Housing

Impeller
Assembly

Hex Bolt
Lock Washer
Flat Washer

BOTTOM VIEW

Chipper
Blade

Flail

Blade

Flail
Blade

Chipper

Blade

Impeller
Assembly