Electrical Needs

The WhisperKOOL System requires a dedicated 110-volt 20-amp circuit. The unit draws a large amount

of amps at initial start up. By designating a dedicated circuit breaker, you will guarantee the unit has

enough power to run effectively. Contact your electrician for installation of this dedicated electrical

circuit.

Electrical Outlet

The unit is equipped with two electrical outlets, one for installation inside the cellar and the other for

installation outside the cellar. The outlet on the inside is covered and has been secured with screws.

Regardless of which side is utilized, the other outlet must then be covered in order to avoid a live elec-

trical charge.

XLT units, built after June 2007, come equipped with a 3-position ON/OFF power switch. The upper po-

sition activates power from the cellar side outlet located on the side of unit. The bottom position activates

power from the rear position outlet. The center position is OFF and is simply used when the owner does

not need to utilize the equipment.

Purchase a surge protector or power conditioner to plug your WhisperKOOL unit into. As with any sen-

sitive electrical equipment, the WhisperKOOL unit’s circuitry may be damaged by power surges and

spikes. Power surges and spikes are not covered by the WhisperKOOL warranty.

Do not use a Ground Fault Interrupter (GFI) with this product. The cooling unit will

draw more amperage than the GFI will allow.
Upon plugging the unit in and turning it on, there will be a five minute delay before

the unit starts. This is based on the function of the thermostat.

INSTALLATION

Sizing Unit to Room

The specification chart will provide information on the unit’s room size cooling capacity. There are cir-

cumstances in which a cellar design may require a larger unit due to some existing design restrictions.

In such a case, we recommend that the customer consider purchasing a unit with a larger capacity to

compensate for the design limitations. Issues such as glass doors, concrete walls and floors may seem

adequate but do not offer the insulation capacity required to maintain the optimum environment.

MODEL

AMPS

AMPS

PRODUCT DIMENSIONS

ROOM SIZE

(starting) (running)

(H x W x D)

(cubic feet)

WK 1600

28.32

4.5

15.75" x 14.25" x 17"

300

WK 3000

30.00

6

15.75" x 14.25" x 17"

650

WK 4200

32.00

9

15.75" x 14.25" x 17"

1000

WK 6000

36.00

9.5

22.5" x 14.25" x 21.25"

1500

WK 8000

36.00

10

22.5" x 14.25" x 21.25"

2000