Vented fireplace logs, Burner assemblies, Accessories – Williams 4235 User Manual
Page 2: Features log sets
©
2008 Williams Furnace Co. Printed in U.S.A. All Rights Reserved Subject to Change without Notice L1140 8/08
Vented Fireplace Logs
Model Number
Log
Length
Btu/hr Input
Dimensions
Front Width/Depth
Shipping
Weight
BURNER ASSEMBLIES
CSA (AGA/CGA) - Equipped with Pilot Safety Kit
IMPORTANT
• Read owner’s manual before using.
• Photographs are representative only.
• Check local codes and ordinances for permitted uses.
• Consult installation manual for clearances prior to
installation.
• We reserve the right to amend product
specifications without notice.
• Installation and servicing recommended by a
qualified service person.
• Please read the warranty for any limitations
or disclaimers. All parts carry a one-year limited
warranty.
• Specify propane or natural gas when ordering. Units
are not intended for conversion between fuel types.
250 West Laurel Street • Colton, Calfiornia U.S.A.
(909) 825-0993 • Fax: (909) 824-8009 or (909) 370-0581
Consumer Line: (888) 256-6465
Homeowner Assistance: (909) 426-0978
www.e-wfc.com
Natural
Propane
Natural
Propane
*
Safety Pilot Kit may be added. Model 4235 for natural gas. Model 4236 for propane gas.
** Add 6” to minimum width (front and rear) if the Gas Valve Safety Pilot Kit is used.
Burner assemblies are interchangeable with all log sets. Both CSA
(AGA/CGA) and RADCO burner assemblies include: Heavy-gauge steel
burner pan, steel bar grate, lava rock, burning embers, complete
hardware for gas connection and damper clamp, sand (natural gas
models) or vermiculite (propane gas models).
CSA (AGA/CGA) listed models are equipped with a safety pilot or
millivolt control system. CSA (AGA/CGA) approved propane models
include vermiculite instead of sand.
Accessories
Gas Valve Safety Pilot Kit
Model 4236 Field converts to propane gas.
Shipping weight 2 lbs.
Model 4235 Field converts to natural gas.
Shipping weight 3 lbs.
A = CSA (AGA/CGA) / R = RADCO / N = Natural / P = Propane / MV = Millivolt
Features
LOG SETS
WH-18R*
75,000
18”
**21” x 16”
30 lbs.
WH-24R*
90,000
24”
**27” x 16”
35 lbs.
WH-30R*
90,000
30”
33” x 16”
40 lbs.
RADCO - Pilot Safety Kit
Optional
CSA (AGA/CGA) - Millivolt Valve
(Remote Control Kit Optional)
- - WH-30AMVP
- - 60,000 30”
39” x 16”
42 lbs.
Model Number
Log
Length
Btu/hr Input
Dimensions
Front Width/Depth
Shipping
Weight
Model Number
Log
Length
Number of Logs
Shipping
Weight
Description
DO-30
SO-18
CB-18
CB-30
30”
18”
18”
30”
8
6
6
8
Classic Designer Oak
Classic Split Oak
Classic Birch
Classic Birch
52 lbs.
31 lbs.
49 lbs.
75 lbs.
WH-18R*
--
40,000 18” 27” x 16”
30 lbs.
WH-24R*
--
45,000 24” 33” x 16”
37 lbs.
WH-30R*
--
45,000 30” 39” x 16”
42 lbs.
--
--
--