Natural

Propane

Thermal AFUE Width

Depth

Height

1403622 1403621 14,000 10,039

76.0

63.0

18"

7⅛" 26¾"

24"

56

2203622 2203621 22,000 16,462

75.0

67.0

32⅛"

10¼"

28"

24"

98

3003622 3003621 30,000 21,849

73.0

66.0

32⅛"

10¼"

28"

24"

100

4007332‡ 4007331‡ 40,000 32,000

80.0

75.0

14⅛"

11¾"

77⅜"

24"

126

4007732 4007731 40,000 32,000

80.0

75.0

14⅛"

11¾"

77⅜"

24"

126

5507332‡ 5507331‡ 55,000 44,000

80.0

76.0

14⅛"

11¾"

87"

24"

140

6257732 6257731 65,500 50,000

80.0

76.0

14⅛"

11¾"

87"

24"

140

Features

Direct-Vent Safety

High-Capacity Blower

Side Outlet Accessories

-

6801

Side-Outlet Register with 10" Boot and Damper for counterflow models · 11 lbs.

6802

Side-Outlet Grille for counterflow models · 2 lbs.

Front Diffusing Grilles

A snap-on grille used to divert heat to the right, left or both directions for
counterflow models only.

6703

Two-Directional Diffuser Grille · 3 lbs.

6704

One-Directional Diffuser Grille · 3 lbs.

Venting Accessories

4318

Vent Shield Deflector · Insulated, galvanized metal sheet · 4 lbs.

9301

15" Vent Extension for 22 and 30,000 Btu/hr Furnaces · 7 lbs.

9302

24" Vent Extension for 22,000 Btu/hr Furnaces · 10 lbs.

9303

24" Vent Extension for 14 and 30,000 Btu/hr Furnaces · 10 lbs.

9304

15" Vent Extension for 14,000 Btu/hr Furnaces · 7 lbs.

9307

Thin Wall Collar · Wall thicknesses from 1" to 5" · 4 lbs.

9308

Vent Cap Guard · Protects pedestrian traffic from heat of the vent cap · 3 lbs.

9806

Counterflow Direct-Vent Tube Extension - 12" Length · 11 lbs.

9807

Counterflow Direct-Vent Tube Extension - 15" Length · 11 lbs.

9808

Counterflow Direct-Vent Tube Extension - 24" Length · 11 lbs.

Finish Items

4701

Trim Strip Accessory · Metal finish moulding strips painted the same color as the
furnace · 4 lbs.

Conversion Kits

-

Btu Size

14,000

8925

8928

22,000

8926

8929

30,000

8927

8930

40,000

7686

7693

55,000

7688

7695

62,500

7689

7696

High Altitude Models

Hard Wire Adapter

-

24V Wall

Model 2303

for 14,000 Btu/hr

* Venting shipped with furnace for 5-9" wall thickness, 24" wall thickness available with use of extension accessories.

‡ Intermittent ignition

Accessories

115V power supply required · 6 lbs.

Direct-Vent Counterflow with Electrical Service Cord

24V Wall
24V Wall

© 2006 Williams Furnace Co. Printed in U.S.A. All Rights Reserved L1171 5/06

Blower is easily added to the furnace. Comes with a fully automatic fan switch.

Natural to

Propane

Propane to

Natural

Model 2302

for 22,000 and 30,000 Btu/hr

All models have ½" gas connection · All models are rated for 4,500' elevation.

24V Wall

Conversion Kit Available

Millivolt Wall
Millivolt Wall
Millivolt Wall

Dimensions

Efficiency %

Type

of

Control

Garage Furnaces

Model Number

Btu/hr

Input

Rating

Btu/hr

Output

Rating

Maximum

Wall

Thickness*

Shipping Weight

(lbs.)

Important

·

Read owner's manual before using/installing.

·

Photographs are representative.

·

Check local codes and ordinances for permitted uses.

·

Consult installation manual for clearances prior to installation.

·

We reserve the right to amend product specifications without notice.

·

Installation and servicing recommended by a qualified service person.

·

Venting must comply with the installation manual.

·

New York approval MEA197-82E Vol 111 on direct-vent models only.

·

Massachusetts approval G3-0305-171

·

Please read the warranty for any limitations for disclaimers.

·

Combustion chamber carries a ten-year limited warranty. All other

parts carry a one-year limited warranty.

2302

Dimensions and Clearances

Direct-Vent (14/22/30 Series)

2" from intersecting wall

18" from top of appliance to ceiling/overhang for 14,000 Btu/hr models

24" from top of appliance to ceiling/overhang for 22,000 and 30,000

Btu/hr models

Direct-Vent Counterflow (40/55/62 Series)

4" from intersecting wall

4" from top of appliance to ceiling/overhang

0" to finished floor

18" from centerline of vent cap on all sides

250 West Laurel Street · Colton, California 92324 USA
(909) 825-0993 · Fax: (909) 370-0581 or (909) 824-8009
Homeowner Assistance: (909) 426-0978
www.wfc-fc.com

COMBUSION

PRODUCTS

VENTED

TO OUTSIDE

COMBUSION

AIR FROM

OUTSIDE

OUTSIDE

COOL ROOM AIR

INSIDE

RADIANT EXT

HEAT

Air Circulation Pattern

WARM ROOM AIR

For clean, comfortable
heat when and where
you want it. The gas
flame is completely
sealed inside, away from
all contact with room air.
Air necessary for
combustion is drawn into
the chamber from
outside through direct
wall vent, and all
combustion products are
vented directly to the
outside. Only clean,
gentle heat, in
continuous circulation is
delivered into the room.
Windows and doors can
stay closed because no
room air is used for
combustion.

Automatic Thermostat -

Included with all Models

Contemporary Finish

"Bird Guard"

"Matchless" Pilot Igniter

All models include a "matchless" pilot igniter and a glass observation
door. Assures convenient pilot lighting without matches.

Light, soft-white powder-coat, scratch-resistant finish to blend
with any décor.

All vent caps include built-in "Bird Guard".

Allows heat to be ducted into a side room.

Current models only · 1 lb.

Model 9940

8925

4701

7696

4318

6704

6703

6703

This manual is related to the following products: