beautypg.com

Gas instructions – weber FLAME User Manual

Page 15

background image

15

GAS INSTRUCTIONS

Check:
1)

Bulkhead fi tting-to-Regulator connection.

ƽ WARNING: If there is a leak at connections (1), turn

OFF the gas. DO NOT OPERATE THE FIREPLACE.
Contact the Customer Service Representative in your
area using the contact information on our web site.
Log onto www.weber.com

®

.

2)

Regulator-to-Quick disconnect fi tting.

3)

Fitting-to-quick disconnect connection.

4)

Test point fi tting

ƽ WARNING: The test point fi tting should only be

loosened or removed by an authorized service person.

5)

Quick disconnect-to-supply connection.

ƽ WARNING: If there is a leak at connection (2), (3), (4)

or (5), retighten the fi tting by hand. Make sure the
quick disconnect fi ttings are properly seated. Recheck
for leaks with soap and water solution. If a leak
persists after these measures, turn OFF the gas. DO
NOT OPERATE THE FIREPLACE. Contact the Customer
Service Representative in your area using the contact
information on our web site. Log onto www.weber.com

®

.

When leak checks are complete, turn gas supply OFF at the source and

rinse connections with water.

(1)

(5)

(2)

(3)

(4)

Table

10-1

Maximum Capacity of Pipe in Cubic Feet of Gas per Hour for Gas Pressures of 0.5 psi or Less and a Pressure Drop of 0.3 Inch

Water Column. (Based on a 0.60 Specifi c Gravity Gas)

Nominal

Iron Pipe

Size

(Inches)

Internal

Diameter

(Inches)

Length of Pipe (Feet)

10

20

30

40

50

60

70

80

90

100

125

150

175

200

1/4

.364

32

22

18

15

14

12

11

11

10

9

8

8

7

6

3/8

.493

72

49

40

34

30

27

25

23

22

21

18

17

15

14

1/2

.622

132

92

73

63

56

50

46

43

40

38

34

31

28

26

3/4

.824

278

190

152

130

115

105

96

90

84

79

72

64

59

55

1

1.049

520

350

285

245

215

195

180

170

160

150

130

120

110

100

1 1/4

1.380

1050

730

590

500

440

400

370

350

320

305

275

250

225

210

1/12

1.160

1600

1100

890

760

670

610

560

530

490

460

410

380

350

320

2

2.067

3050

2100

1650

1450

1270

1150

1050

990

930

870

780

710

650

610

2 1/2

2.469

4800

3300

2700

2300

2000

1850

1700

1600

1500

1400

1250

1130

1050

980

3

3.068

8500

5900

4700

4100

3600

3250

3000

2800

2600

2500

2200

2000

1850

1700

4

4.026

17500

12000

9700

8300

7400

6800

6200

5800

5400

5100

4500

4100

3800

3500

© 1997 National Fire Protection Association, Inc,. and International Approval Services - U.S., Inc. All Rights Reserved.