Gas instructions – weber FLAME User Manual
Page 15

15
GAS INSTRUCTIONS
Check:
1)
Bulkhead fi tting-to-Regulator connection.
ƽ WARNING: If there is a leak at connections (1), turn
OFF the gas. DO NOT OPERATE THE FIREPLACE.
Contact the Customer Service Representative in your
area using the contact information on our web site.
Log onto www.weber.com
®
.
2)
Regulator-to-Quick disconnect fi tting.
3)
Fitting-to-quick disconnect connection.
4)
Test point fi tting
ƽ WARNING: The test point fi tting should only be
loosened or removed by an authorized service person.
5)
Quick disconnect-to-supply connection.
ƽ WARNING: If there is a leak at connection (2), (3), (4)
or (5), retighten the fi tting by hand. Make sure the
quick disconnect fi ttings are properly seated. Recheck
for leaks with soap and water solution. If a leak
persists after these measures, turn OFF the gas. DO
NOT OPERATE THE FIREPLACE. Contact the Customer
Service Representative in your area using the contact
information on our web site. Log onto www.weber.com
®
.
When leak checks are complete, turn gas supply OFF at the source and
rinse connections with water.
(1)
(5)
(2)
(3)
(4)
Table
10-1
Maximum Capacity of Pipe in Cubic Feet of Gas per Hour for Gas Pressures of 0.5 psi or Less and a Pressure Drop of 0.3 Inch
Water Column. (Based on a 0.60 Specifi c Gravity Gas)
Nominal
Iron Pipe
Size
(Inches)
Internal
Diameter
(Inches)
Length of Pipe (Feet)
10
20
30
40
50
60
70
80
90
100
125
150
175
200
1/4
.364
32
22
18
15
14
12
11
11
10
9
8
8
7
6
3/8
.493
72
49
40
34
30
27
25
23
22
21
18
17
15
14
1/2
.622
132
92
73
63
56
50
46
43
40
38
34
31
28
26
3/4
.824
278
190
152
130
115
105
96
90
84
79
72
64
59
55
1
1.049
520
350
285
245
215
195
180
170
160
150
130
120
110
100
1 1/4
1.380
1050
730
590
500
440
400
370
350
320
305
275
250
225
210
1/12
1.160
1600
1100
890
760
670
610
560
530
490
460
410
380
350
320
2
2.067
3050
2100
1650
1450
1270
1150
1050
990
930
870
780
710
650
610
2 1/2
2.469
4800
3300
2700
2300
2000
1850
1700
1600
1500
1400
1250
1130
1050
980
3
3.068
8500
5900
4700
4100
3600
3250
3000
2800
2600
2500
2200
2000
1850
1700
4
4.026
17500
12000
9700
8300
7400
6800
6200
5800
5400
5100
4500
4100
3800
3500
© 1997 National Fire Protection Association, Inc,. and International Approval Services - U.S., Inc. All Rights Reserved.