beautypg.com

Laser/radar alerts, Mode alerts, Alert priority – Whistler XTR-190 User Manual

Page 6: Troubleshooting, Reset features

background image

Speed Radar Audio/Visual Alerts

When X, K, or Ka band is detected, the band ID
and signal strength is displayed. The audio alert
is continuous and has a geiger counter-like
pattern. The faster the beep, the closer or
stronger the radar source.

“II” = weak signal, “IIIIII” = strong signal

“K

K//K

Ka

a” Icon will flash for K

Ka

a detection

Laser Audio/Visual Alerts

When a laser signal is detected, the “V

V//L

L” will

be illuminated.

Pulse Protection

®

Pulse (or instant-on) radar is more difficult to
detect than conventional radar because it
remains off until activated to measure the speed
of a targeted vehicle.
When a pulse type transmission is detected, your
Whistler detector sounds an urgent 3-second
audio warning and the display will show a max
signal strength level.

M

Ma

axx S

Siig

gn

na

all

After the 3-second pulse alert, the standard alert
pattern continues for as long as the signal is
present.
It is important to respond promptly to a pulse
alert, since warning time may be minimal.

LASER/RADAR ALERTS

Alert Priority

When two or more signals are received at the
same time, the alert priority is:
1. Laser
2. VG-2
3. Speed Radar
4. Safety Radar
Example:
If X band is alerting, then suddenly a VG-2
signal is detected, the VG-2 warning will
override the X band alert.

POP

MODE ALERTS

POP

Mode Alerts

Because POP

Mode travels on regular radar

bandwidth, there is no particular alert for POP

Mode transmissions. POP

Mode alerts will be

displayed as a regular radar alert.

ALERT PRIORITY

Reset Features

All user features can be reset to factory settings.

• Unplug Power Cord from unit.
• Remove Batteries.
• Press and hold Power and Quiet.
• Plug Power Cord into unit.
• Wait for 2 beeps.
• Release Power and Quiet buttons.
Unit is now reset to the following features
and settings.

Default factory settings are:

1. Audio to level (4)
2. Display shows “H

H”

3. Auto Quiet Mode OFF
4. VG-2 Detection Mode OFF
5. Auto Shut Off to 1 hour
6. Full Power Up sequence
7. Dim/Dark to full Illumination

TROUBLESHOOTING

Your Whistler detector is expertly engineered
and designed to exacting quality standards to
provide you with reliable, trouble-free operation.
If your unit has been correctly installed following
the guidelines in this manual, but is not
operating optimally, please refer to the
troubleshooting guide below.

PROBLEM: No display or audio.
• Make sure batteries are installed with the

correct polarity.

• Make sure batteries are fully charged.
• Make sure battery contacts are clean.
• Check fuse in Whistler plug; replace if

necessary with a 2 amp 3AG type.

RESET FEATURES

14

15

16

This manual is related to the following products: