FEATURES & OPERATING CONTROLS (continued)

3


8



FILTER PUMP SWITCH
(ON-OFF)

ON position energizes FILTER PUMP and causes oil in
RESERVOIR (10) to be pumped back into frypot.

OFF position de-energizes FILTER PUMP.

NOTE: POWER SWITCH (1) must be in FILTER position for
FILTER PUMP to operate.

9

HI-LIMIT THERMOSTAT

Provides over-temperature protection by de-energizing HEATING
ELEMENTS should oil temperature exceed factory pre-set limits.

10 TEMPERATURE CONTROL

THERMOSTAT

Controls oil temperature. Range: 250ºF (121ºC)
375ºF (191ºC)

11


DRAIN VALVE LEVER

Opens and closes the DRAIN VALVE:
Turn counterclockwise (vertical) to OPEN
Turn clockwise (horizontal) to CLOSE

12 POWER OUTLET BOX

Electrical service connection TERMINAL BLOCK located here.

13

OIL FILTER RESERVOIR

Collects oil from FRYPOT for filtering or disposal.
Holds filter screen, filter paper & filter paper holder.

14

FILTER PUMP MOTOR
RESET BUTTON
(located at rear of motor)

FILTER PUMP MOTOR is equipped with an overheating
protection device.
RESET must be performed manually. Allow motor to cool for
approx. 30 min, then firmly press the red button.

15 FRY

BASKET

Holds product to be cooked.

16


BASKET HANDLE

Used to manually raise and lower FRY BASKET into and out of
FRYPOT.

REMOVE FROM BASKET BEFORE ACTIVATING TIMER!

17 DRIP

PAN

Collects liquids that accumulate on top of fryer.

LIFT CRADLE
(see page 8)

Lowers fry basket into frypot during cook cycle. Automatically
raises from frypot at end of cook cycle

FRYPOT COVER
(see front cover)

Hinged cover. When tilted forward, rises and lowers with cradle
lift. When tilted back, remains open during cook cycle

WARNING:

FIRE HAZARD / HOT OIL

The HI-LIMIT THERMOSTAT is a FIRE PROTECTION DEVICE.

If tripping persists, clean debris from the space between the

hi-limit bulb and the element to enhance oil flow and facilitate reset.

Otherwise, contact your authorized Wells Service Agent for repairs.

DO NOT ATTEMPT TO BYPASS OR HOLD IN THE BUTTON OF

THE HI-LIMIT THERMOSTAT. A SERIOUS FIRE MAY RESULT.

WARNING

361

301

669

OpM

anual

for

W

F

A

E

-30

F

Ele

c

tric Fr

yer

NOT S

H

OW

N