Warning, Features & operating controls (continued), Fire hazard / hot oil – Wells WFAE-30F User Manual
Page 5
FEATURES & OPERATING CONTROLS (continued)
3
8
FILTER PUMP SWITCH
(ON-OFF)
ON position energizes FILTER PUMP and causes oil in
RESERVOIR (10) to be pumped back into frypot.
OFF position de-energizes FILTER PUMP.
NOTE: POWER SWITCH (1) must be in FILTER position for
FILTER PUMP to operate.
9
HI-LIMIT THERMOSTAT
Provides over-temperature protection by de-energizing HEATING
ELEMENTS should oil temperature exceed factory pre-set limits.
10 TEMPERATURE CONTROL
THERMOSTAT
Controls oil temperature. Range: 250ºF (121ºC)
375ºF (191ºC)
11
DRAIN VALVE LEVER
Opens and closes the DRAIN VALVE:
Turn counterclockwise (vertical) to OPEN
Turn clockwise (horizontal) to CLOSE
12 POWER OUTLET BOX
Electrical service connection TERMINAL BLOCK located here.
13
OIL FILTER RESERVOIR
Collects oil from FRYPOT for filtering or disposal.
Holds filter screen, filter paper & filter paper holder.
14
FILTER PUMP MOTOR
RESET BUTTON
(located at rear of motor)
FILTER PUMP MOTOR is equipped with an overheating
protection device.
RESET must be performed manually. Allow motor to cool for
approx. 30 min, then firmly press the red button.
15 FRY
BASKET
Holds product to be cooked.
16
BASKET HANDLE
Used to manually raise and lower FRY BASKET into and out of
FRYPOT.
REMOVE FROM BASKET BEFORE ACTIVATING TIMER!
17 DRIP
PAN
Collects liquids that accumulate on top of fryer.
LIFT CRADLE
(see page 8)
Lowers fry basket into frypot during cook cycle. Automatically
raises from frypot at end of cook cycle
FRYPOT COVER
(see front cover)
Hinged cover. When tilted forward, rises and lowers with cradle
lift. When tilted back, remains open during cook cycle
WARNING:
FIRE HAZARD / HOT OIL
The HI-LIMIT THERMOSTAT is a FIRE PROTECTION DEVICE.
If tripping persists, clean debris from the space between the
hi-limit bulb and the element to enhance oil flow and facilitate reset.
Otherwise, contact your authorized Wells Service Agent for repairs.
DO NOT ATTEMPT TO BYPASS OR HOLD IN THE BUTTON OF
THE HI-LIMIT THERMOSTAT. A SERIOUS FIRE MAY RESULT.
WARNING
361
301
669
OpM
anual
for
W
F
A
E
-30
F
Ele
c
tric Fr
yer
NOT S
H
OW
N