beautypg.com

Warning, Burner flames, Stacking – Whirlpool UG1H5040T3NOV User Manual

Page 19: Emergency shut down, Water temperature regulation

background image

19

The thermostat is adjusted to its lowest temperature when
it is shipped from the factory. Water temperature can be
regulated by moving the temperature dial to the preferred
setting. The preferred starting point is 120°F. Align the
index bar on the thermostat with the desired water
temperature as shown in Figure 19. There is a hot water
scald potential if the thermostat is set too high.

NOTE: During low demand periods when hot water is not
being used, a lower thermostat setting will reduce energy
losses and may satisfy your normal hot water needs. If hot
water use is expected to be more than normal, a higher
thermostat setting may be required to meet the increased
demand. When leaving your home for extended periods
(vacations, etc.) turn the temperature dial to its lowest
setting. This will maintain the water at low temperatures
with minimum energy losses and prevent the tank from
freezing during cold weather.

Figure 18

Flame Characteristics

Correct flame

soft blue

Water temperature over 125°F can cause
severe burns instantly or death from scalds.

Children, disabled and elderly are at highest
risk of being scalded.

Feel water before bathing or showering.

Temperature limiting valves are available.

WARNING

Burner Flames

Inspect burner
flames through
viewport.
Flames should
be very small
with a blue
haze and
small amounts
of yellow or
orange at the
edges. After
several minutes
of operation the
burner screen may glow red. If large flames are observed
at anytime shut-off unit and call a qualified person.

Stacking

Stacking occurs when a series of short draws of hot water
(3 gallons or less) are taken from the water heater tank.
This causes increased cycling of the burner and can result
in increased water temperatures at the hot water outlet. An
anti-scald device is recommended in the hot water supply
line to reduce the risk of scald injury.

Emergency Shut Down

IMPORTANT: Should overheating occur or the gas supply
fails to shut off, turn off the water heater’s manual gas
control valve and call a qualified person.

Water Temperature Regulation

IMPORTANT: Adjusting the thermostat past 120°F on the
temperature dial will increase the risk of scald injury in the
times shown below.

CA

UTION

W

AT

ER INCREAS

ES

HOTTER

TH

E

RIS

K OF SCALD

IN

JU

R

Y

VA

C

AT

ION

WAR

M

H

O

T

120°F

Bar

130°F

Bar

Reset
Button

Gas Control Knob

Dial Stop

Index
Bars

Temperature Dial

Gas Control Knob

(Off-PIlot-On)

Index Bar

Temperature Dial

130°F

Mark

120°F

Mark

Figure 19

Gas Valve/Thermostat

Settings

White Rodgers Gas Valve

Robertshaw Gas Valve

Water

Temperature °F

Time for 1st

Degree Burn

(Less Severe Burns)

Time for

Permanent Burns

2nd & 3rd Degree
(Most Severe Burns)

110
116
116

122
131
140
149
154

(normal shower temp.)

(pain threshold)

35 minutes

1 minute

5 seconds
2 seconds

1 second

instantaneous

45 minutes

5 minutes

25 seconds

5 seconds
2 seconds
1 seconds

(U.S. Government Memorandum, C.P.S.C., Peter L. Armstrong, Sept. 15,1978)