beautypg.com

Troubleshooting suggestions – Wells F-49RT User Manual

Page 10

background image

DESCRIPTION

POSSIBLE PROBLEM

SUGGESTED REMEDY

Unit will not heat

Not plugged in or circuit breaker
tripped

Plug into proper receptacle
Reset circuit breaker

Temperature control knob not set to
desired temperature

Set to desired temperature

Hi-limit safety tripped

Clean element

1

, reset hi-limit

Damaged internal component

Contact Wells Authorized Service
Agency for repairs

Unit will not maintain
temperature

Temperature control thermostat
thermobulb contaminated with
cooking debris

Clean element

2

Damaged internal component

Contact Wells Authorized Service
Agency for repairs

Unit leaks water

Damaged water pot

Replace water pot (frypot)

Element head will not
raise, will not stay in the
up position, or will not
lower

Water pot out of position, or has
excess cooking debris in bottom

Check water pot for position
Clean water pot

1

The hi-limit safety is designed to shut down the unit if water pot is allowed to boil dry and temperature

exceeds 275ºF. However, a build-up of cooking debris between the heating element and the

thermobulb of the hi-limit safety will cause the hi-limit to trip prematurely. Clean the element so that

water may circulate freely between the element and the thermobulb. Reset the safety by pressing the

red button on the back of the element head.

2

A build-up of cooking debris between the heating element and the thermobulb temperature control

thermostat will cause inconsistent temperatures. Clean the element so that water may circulate freely

between the element and the thermobulb.

TROUBLESHOOTING SUGGESTIONS

8

Damaged hinge bracket or support
rod

Contact Wells Authorized Service
Agency for repairs

351 p

/n 3
04366

O
p

M

Countertop

Rethermali

z

e

r F-49RT