Install Quick Specs are for planning purposes only. Please refer to the detailed installation 
instructions, prior to making any cutouts. 
Externally Mounted Ventilators – Install Quick Specs
VEN150E
Installation Type & Discharge Direction 
Mounted outside. Can be mounted on exterior 
roof or wall. 
CFM Rating
1500 CFM 
 
Minimum Duct Size 
10” round 
 
Maximum Equivalent Straight Duct Length 
50 feet 
 
Equivalent Straight Lengths 
• 1 foot of 8” or 10” duct = 1 foot 
• 1 foot of 3 ¼” x 14” rectangular = 1 foot
• 8” round 90 degree Elbow = 5 feet 
• 10” round 90 degree Elbow = 3 feet 
• Wall or Roof Cap = 2 feet
Standard
Features
• Adaptable to all Wind Crest hoods
• Weather-resistant glavanized steel
construction
• Thermally protected, permanently
lubricated motor
• Dynamically balanced 12” diameter blower
wheel
• Neoprene resilient anti-vibration mounted
• Built-in Flashing plate for roof or wall mount
• Easily removed blower cover for periodic
cleaning
 
Ventilator Motor Ratings* 
Hoods without Heat Lamps: 
12.0 Amps @ 120 V AC, 60 Hz 
Hoods with Heat Lamps: 
16.4 Amps @ 120 V AC, 60 Hz 
 
*20 Amps @ 120 V AC, 60 Hz required when 
using VEN150E ventilator. 
 
Ventilator Carton Weight: 
VEN150E = 80 lbs. 
 
 
7"
4"
24
"
30"
 
 
 
 
UL
UL
LISTED 7Z66 C
 
 
 
 
 
 
 
 
 
 
 
VEN150E