Configuration menu, Installer/configuration menu – White Rodgers 1F85-277 User Manual
Page 6

6
Press the SYSTEM button until OFF is displayed, then press the
and
simultaneously
INSTALLER/CONFIGURATION MENU
Press
Displayed
Press
or
Step
Button(s)
(Factory Default)
to select
Comments
1
System
MS 2
SS1, HP2, HP1
Selects Single stage, Multi-stage, or Heat Pump
(Single stage or 2-stage) System Configuration
2
System
7d
5d, 0d
Selects Programs Per Week
3
System
PRG 4
PRG 2
Selects Programmable Periods (PRG 2 = 2
programmable periods; PRG 4 = 4 programmable periods)
4
System
4:00 HOLD
0:15 to 4:00
Selects Temporary Program Override Time
(increments of 15 minutes)
5
System
EMR
OFF
Selects Energy Management Recovery OFF or ON
(ON)
6
System
FA
SL
Selects Fast or Slow Cycle Selection
7
System
CL
CL
Selects Compressor Lockout CL OFF or ON
(OFF)
(ON)
8
System
CDL
CDL
Selects Backlight Display
(ON)
(OFF)
9
System
FA
FA
Selects Fast Second Stage ON or OFF
(ON)
(OFF)
10
System
0 FLTR
50-1950 (increments of 50)
Selects filter replacement run time
11
System
0°F
4 LO to 4 HI
Selects Temperature Display Adjustment 4 LO to 4 HI
(Room Temperature)
12
System
°F
°C
Selects temperature display F° or °C selection
13
System
AU On
OFF
Selects AUTO Mode ON or OFF
14
System
LR
LR 62 to LR89
Selects Limited HEAT range
(90)
15
System
LR
LR 46 to LR 82
Selects Limited COOL range
(45)
16
System
CA
CA
Feature Not Available
(OFF)
(ON)
17
System
(ON)
Selects Keypad Lockout
(OFF)
18
System
0
001 to 999
Selects Keypad lockout combination number
Press System to set code
19
Run
Returns to the OFF position
CONFIGURATION MENU
CONFIGURATION MENU
CONFIGURATION MENU
CONFIGURATION MENU
CONFIGURATION MENU
programmable, SYSTEM button selection will skip
Programmable periods (item 3), programmable hold time
(item 4) and EMR (item 5).
3) Programmable Periods – This control can be configured
for 4 or 2 programmable periods. The display indicates
“PRG 4” in the display as default. The programmable
periods can be toggled to “PRG 2” by pressing the
or
keys.
4) Select Temporary Program Override Time – The thermo-
stat can hold any temperature you set it to for the amount
of time you select on this option. Your choices are 0:15 to
4:00 hours in 15 minute increments.
Example:
a. You have selected 3:00 hours for the Temporary Pro-
gram Override time period.
b. With the thermostat set to Heat or Cool, press
or
to set the temperature to your preference.
The thermostat will maintain this temperature setting
for 3 hours with “HOLD” blinking to remind you it is
in Temporary Hold. After 3 hours, the thermostat will
go back to the program temperature and “HOLD” will
no longer blink or display.