Outside location for vent terminal – Williams 1773511 User Manual

Page 6

background image

5

A. Clearance above grade, veranda, porch, deck or

balcony 12-inches (30 cm) minimum.

(3)

B. Clearance to window or door that may be opened 12-

inches (30 cm) minimum.

(3)

C. Clearance to permanently closed window minimum 12-

inches (30 cm) recommended to prevent condensation
on window.

D. Vertical clearance to ventilated soffit located above the

terminal within a horizontal distance of 2-feet (60 cm)
from the centerline of the terminal 18-inches (46 cm)
minimum.

E. Clearance to unventilated soffit 12-inches (30 cm)

minimum clearance to vinyl soffit 36-inches (90 cm)
minimum.

F. Clearance to outside corner 12-inches (30 cm)

minimum.

G. Clearance to inside corner 18-inches (46 cm) minimum.

H. Not to be installed above a meter/regulator assembly

within 3-feet (90 cm) horizontally from the centerline of
the regulator.

(3)

I. Clearance to service regulator vent outlet 6-feet (1.8 m)

minimum.

(3)

J. Clearance to nonmechanical air supply inlet to building

or the combustion air inlet to any other furnace 12-
inches (30 cm) minimum.

(3)

K. Clearance to a mechanical air supply inlet 6-feet (1.8 m)

minimum.

(3)

L. Clearance

(1)

above paved sidewalk or a paved driveway

located on public property 7-feet (2.1 m) minimum.

(3)

M. Clearance under veranda, porch, deck or balcony 12-

inches (30 cm) minimum.

(2),

(3)


Notes:

(1)

A vent shall not terminate directly above a sidewalk
or paved driveway which is located between two
single family dwellings and serves both dwellings.

(2)

Only permitted if veranda, porch, deck or balcony is
fully open on a minimum of two sides beneath the
floor.

(3)

As specified in CGA B149 installation codes (1991).

Note: Local codes or regulations may require different
clearances.




Figure 1











1 = Fixed/Closed

2 = Openable

V = Vent Terminal

A = Air Supply

1 = Fixed/Closed

2 = Openable

V = Vent Terminal

A = Air Supply
































Outside Location for Vent Terminal

Outside Location for Vent Terminal

Upon delivery, check to make sure the packaging has not been damaged.

Upon delivery, check to make sure the packaging has not been damaged.

1. Remove the furnace from box/packaging taking care not to damage the paper template to be used to mark the holes for

mounting the furnace.

1. Remove the furnace from box/packaging taking care not to damage the paper template to be used to mark the holes for

mounting the furnace.

2. After marking where the appropriate holes will be, using the above mentioned template, make a 2-inch (50.8 mm) diameter

hole.

2. After marking where the appropriate holes will be, using the above mentioned template, make a 2-inch (50.8 mm) diameter

hole.

3. Cut the combustion exhaust and fresh air inlet tubes according to the wall thickness (Figure 2):

Air inlet tube length = wall thickness + 3/32-inches (2.4 mm)

F

Flue outlet tube length = wall thickness + 1-5/16-inches (7.9 mm)

3. Cut the combustion exhaust and fresh air inlet tubes according to the wall thickness (Figure 2):

Air inlet tube length = wall thickness + 3/32-inches (2.4 mm)

F

Flue outlet tube length = wall thickness + 1-5/16-inches (7.9 mm)

4. Drill the mounting holes “A” (5 holes) in the wall. If possible use self-tapping screws, drill 1/8-inch diameter holes. If self-

tapping screws cannot be used, drill 1/4-inch diameter holes and use the plastic anchors provided.

4. Drill the mounting holes “A” (5 holes) in the wall. If possible use self-tapping screws, drill 1/8-inch diameter holes. If self-

tapping screws cannot be used, drill 1/4-inch diameter holes and use the plastic anchors provided.

This manual is related to the following products: