beautypg.com

70series, Single stage, White-rodgers – White Rodgers 1E78-140 User Manual

Page 2: Printout made at 100% of final size

background image

Job #

WRDG 106526

File Name

106526_70sUnvrslFlyer_Back.ai

Part #
ProLeader SeanH
Updates hd11.19.04,amk11.21.04,amk11.30.04,
amk120304,hd12.08.04,

JVS.12.08.04,

hd12.09.04,

shsPF121404

Printing & Finishing: 4/C Offset

8.5"

11"

THIS PRINTOUT IS FOR REFERENCE ONLY!

Do not use this printout for color match or critical dimensions.

Printout made at 100% of final size.

THIS FILE HAS NOT BEEN TRAPPED.

This file was created with Adobe Illustrator 7.0.
DO NOT try to open this file with earlier versions.
Marketing Support Inc. assumes no responsibility for final print quality and
will not be held liable for errors or omissions due to alterations made to this
document by client, film or print vendor.
MSI requires a Chromalin or color key type proof for final approval.

If you have any questions about this file, or require further assistance,
contact MSI at 312-565-0044 .

CYAN

MAGENTA

YELLOW

BLACK

Series

System

Programs

Power Source

Hardwired

90 - Premium

80 - Standard

70 - Economy

Single Stage
Multi-Stage
Heat Pump

Non-programmable

5/2 day

5/1/1 day

7 day

Battery

Hardwired/battery

Power stealing w/battery back-up

Application Guide

Single Stage

Digital 5/2 Day
Programmable and
Non-Programmable
Battery

70Series

White-Rodgers

1E78-140

Single Stage/Heat

Non-Programmable
T h e r m o s t a t

1E78-144

Single Stage

Non-Programmable
T h e r m o s t a t

1E78-151

Single Stage

2 Programs
T h e r m o s t a t

Wall Plate F61-2593

F4-1748 Subbase mounted on 2" x 4" Junction

Box with 1D78-140 “New Construction Stat”

“New Construction Stat”

1D78-140

www.white-rodgers.com

St. Louis, Missouri

314-577-1300

Markham, Ontario

905-201-4701

Controlling Indoor Comfort Worldwide

Since 1937

WR-6526

Terminal Designations

1E78-151, 1E78-144 and F4-1748

RC

RH

Y

W

O

G

B

1E78-140

RH

W

The Emerson logo is a trademark and
a service mark of Emerson Electric Co.

E C O N O M Y

Dimensions

3.25"W x 5.3"H x 1.1"D

Electrical Specifications

Rating
0 to 30 VAC, 50/60 Hz or DC

0.05 to 1.0 Amp (load per terminal)

1.5 Amps maximum load (all terminals
combined)

Standard Systems
Single stage gas, oil, electric

Single stage heat pump
(1E78-151 and 1E78-144)

Millivolt compatible

Thermal Specifications

Setpoint Temperature Range: 45

° to 90°F

(7

° to 32°C)

Rated Differential: 0.6

° to 1.9°F with adjustable

anticipation

Operating Ambient Temperature: 32

° to 105°F

(0

° to 40°C)

Operating Humidity Range: 90%
non-condensing maximum

Shipping Temperature Range: -4

° to 150°F

(-20

° to 65°C)

Accessories

Wall Plate F61-2593 (4.5"W x 6.6"H)

Subbase F4-1748 (3.25"W x 5.3"H)

“New Construction Stat” 1D78-140 with
heat only 65

° setpoint

Thermostat Guard F29-0143

(For additional guard options refer to White-Rodgers catalog.)

For Additional Information

Visit www.white-rodgers.com

This manual is related to the following products: