Models whcf-suf and whcf-sufc, Under sink main f a ucet fil tra tion, Installation,use & care guide – Whirlpool WHCF-SUF User Manual
Page 2: Installation instructions, Tools needed, Parts and materials included, Using push-in fittings” installation requirements, 1 ye ar limited warranty, Ultraease, Filtrationsystem and ultraease
Models
WHCF-SUF and WHCF-SUFC
1 Ye
ar Limited
Warranty
CUNOIncor
porated w
arrants the or
iginal purchaser-consumer of its Product
that is free of defects in mater
ials and wo
rkmanship
.A
ny
defect, malfunction, or
other failure of the Product to conf
orm to this w
arranty will be remedied b
y
Warr
antorin the manner pro
vided below
.
This W
arranty
, together with any w
arranties implied b
y la
w, shall be limited to a
duration of one (1) y
ear from the original date of purchase b
y the consumer
.
This W
arranty does not apply to def
ects that result from abuse
, misuse, alter-
ation or damage not caused by
CUNOIncor
porated.
THISW
ARRANTYDOES NO
T COVER, AND IS INTENDED
TO
EXCLUDE ANY
LIABILITY ON THE P
AR
T OF
WARRANT
OR, WHETHER UNDER
THIS W
AR-
RANTY OR UNDER ANY W
ARRANTY IMPLIED BY LAW
, FOR ANY INDIRECT
OR CONSEQUENTIAL D
AMAGES FOR BREA
CH HEREOF OR THEREOF
.
Note:Some states prohibit limitations on the dur
ation of implied warr
anties and
on the exclusion of indirect or consequential damages;
and so the limitation on
implied warr
anties and on incidental and consequential damages may not be
applicable to y
ou.
RESPONSIBILITY OF W
ARRANTOR
CUNOIncor
porated’
s responsibility under this warr
anty shall be to repair at its
expense
, at no charge to the original purchaser-consumer an
y product that is
actually defectiv
e, malfunctioning or otherwise in violation of this w
arranty
.I
f
CUNOIncor
porated f
or any reason cannot repair a Product co
vered hereb
y
within two (2) w
eeks after receipt of the original purchaser-consumer’
s notifica-
tion of a W
arranty claim and the Product, then CUNO
Incorpor
ated’s responsi-
bility shall be, at its option, either to replace the def
ective Product with a compa-
ra
ble ne
w unit at no charge to the consumer or to refund the full purchase price
.
CUNOIncor
porated’
s obligations of repair
, replacement, or refund are condi-
tioned upon the return of the def
ective product to CUNO
Incorpor
ated.
If any Product hereb
y is actually defectiv
e within the terms of this
Warr
anty , then
CUNOIncor
porated will bear all the reasonab
le and proper shipping and mail-
ing charges actually incurred in the consumer’s retur
n of the Product set fo
rth
herein.If the Product pro
ves not to be def
ective within the ter
ms of this
Warr
anty , then all costs and e
xpenses in connection with the processing of the
consumer’s claim hereunder shall be bor
ne by
the consumer.
RESPONSIBILITY OF THE CONSUMER
The original purchaser-consumer’
s sole responsibility in the instance of a wa
r-
ranty claim shall be to notify CUNO
Incorpor
ated of the defect, malfunction or
other manner in which the terms of this
Warr
anty are violated.Y
ou may secure
perfor
mance or obligations hereunder b
y (in wr
iting):
1.
Identifying the Product involv
ed (by model or ser
ial number or other sufficient
description that will allo
w W
arrantor to deter
mine which product is defectiv
e).
2.
Specifying where, when and from whom the Product w
as purchased.
3.
Describing the nature of the def
ect, malfunction or other violation of this
Warr
anty .
4.
Return the Product, with the abo
ve
info
rmation to:
CUNOIncorporated,
400 Researc
hP
arkway,
Meriden,CT 06450,
U.S.A.
THIS W
ARRANTY GIVES Y
OU SPECIFIC LEGAL RIGHTS, AND
YOU MA
Y
ALSO HAVE O
THER RIGHTS,
WHICH V
AR
Y FR
OM ST ATE
TO
ST ATE.
UNDER SINK MAIN F A
UCET
FIL TRA
TION
UltraEase
™
FiltrationSystem and
UltraEase
™
PLUS FiltrationSystem
Installation,Use &
Care Guide
8559764/INSTR7014 1203
04/04
INSTR7014 1203
Whirlpool
Water Products
400 Research Pa
rk
wa
y , P
.O
.Bo
x 765
8559764
Meriden, CT 06450 U
.S
.A.
Filter Replacement:
The contaminants or other substances removed or reduced b
y
this water filter are not necessar
ily in all users’w
ater.
Filter life v
aries depending on local w
ater conditions and the v
ol-
ume of water used.
We
recommend that you change y
our filter
ever
y 6 months.H
ow
ever
, it can be replaced earlier if there is a
drop in pressure at the faucet.
T o reduce Chlor
ine Taste and Odor and Cysts
,
use Replacement Filter:
WHCF-SRC
T o reduce Sediment and Chlor
ine Taste and Odor
,
use Replacement Filter:
WHCF-SR
Do not use with water that is microbiologically unsaf
e or of unknown quali-
ty without adequate disinfection bef
ore or after the system.
Systems certified f
or Cyst reduction may be used on disinf
ected water
that may contain filter
able cysts
.E
P A
Establishment
#070595-CT -001
Filter Cartridg
e Replacement Instructions:
T o remo
ve old filter:T
urn
filter 1/4 turn to the left.
T op surf
ace
of filter will move
aw
ay from the bottom of the head.
Pull filter
down to disengage
.
T o inser
t new filter:
Push filter into Filter Head/Brac
ket.
T ur
n filter
1/4 turn to the r
ight until it stops
.T
op surface of filter will become
flush with bottom of the Filter Head/Brac
ke
t when fully engaged.
Label will face f
orward.
Flush filter for 5 min
utes to remove
air.
T roub
leshooting Guide
Water Leaks at
Threaded Fittings:
Tighten slightly more until leak stops.
Water leaks at Push-in Connections
Push tubing in as far as it will go
.If leaking contin
ues, shut off
water at the or
iginal valv
e and remove
water line b
y pushing in on
the connector collar while pulling the tubing aw
ay.
Use a catch
basin (See Push-in Fittings Section) Inspect tubing for cr
acks and
scratches
.If tubing is cr
acked or scr
atched, cut that portion a
wa
y
and reinsert tubing into fitting.
Make sure tubing is cut str
aight.If not, recut.
HelpLine 1-866-245-9474
Monday Thr
ough Frida
y
8:00a.m.
to 9:00 p.m.
EST
or write us at
Whirlpool Water
Products
PO Box 765
Meriden,CT 06450
® Registered tr
ademark/TM
T rademar
k of Whir
lpool, USA,
used under license.
© 2004
Whirlpool Cor
poration.
All rights reser
ved.
® Marca registr
ada/TM Marca de comercio de Whir
lpool, USA,
usado bajo licencia.
T odos los derechos reser
vados
.
6. Referring to section “Using
Push-In Fittings,” insert a sec-
tion of the plastic tubing into
faucet adapter fitting, making
sure end of tubing is firmly seat-
ed to backstop.
Hold the filter head/bracket
away from the wall, press other
end of tubing into outlet side as
indicated by arrow on Filter
Head/Bracket. (See Figure 4,
A.)
7. Take the remaining section
of tubing, slide the compres-
sion hex nut and 3/8” ferrule
(tapered end away from com-
pression hex nut) onto the
tubing and put in the tube
insert (see Figure 5). Fasten
this assembly onto 3/8” cold
water supply outlet. Do not
overtighten (see Figure 6).
Overtightening will cause tub-
ing to separate from fitting.
Connect other end to the inlet
side as indicated by the arrow
on Filter Head/Bracket (see
Figure 4, B).
8. Place Filter Head/Bracket
holes over mounting screws,
press down to lock into place and tighten screws for a
snug fit.
9. Insert filter into Filter Head/Bracket. Turn filter 1/4 turn
to the right until it stops. Top surface of filter will become
flush with bottom of the Filter Head/Bracket when fully
engaged. Label will face forward.
10. Turn on water and open faucet to flush air from the
system. Run water for 5 minutes to flush out air. Check for
leaks.
Close sink faucet. System is now ready for use!
1. Filter Cartridge
2. Filter Head/Bracket
3. 5’ of 3/8” Tubing
4. 3/8” x 1/2” Faucet Adapter
5. 3/8” Compression Hex Nut
6. 3/8” Ferrule
7. 3/8” Tube Insert
8. #2 Phillips Mounting Screws
• Phillips Head Screwdriver
• Adjustable Wrench
• Utility knife or tube cutter for copper tubing
Installation Instructions
For Use With Cold Water Only
NOTE: Remove items from under the sink. Place a catch basin there
to collect small amounts of water that may run out when disconnecting
water supply lines.
1. Turn off cold water supply valve and remove existing water supply
tubing and/or fitting.
2. Select and mark a location under the sink that allows access for fil-
ter change.
3. Using filter head/bracket as a guide, fasten Filter Head/Bracket to
wall with #2 Phillips mounting screws supplied.
Mark hole locations so that there is 1 1/2”
between the screws (see Figure 1), from
center of each screw. When installed, filter
bottom should be at least 2 1/2” from sink
cabinet floor to facilitate cartridge change.
Install screws, but only halfway, so you can
easily slip the bracket to wall before firmly
setting screws.
4. Determine length of tubing required from
filter head/bracket to faucet and from water
supply line to filter head/bracket by holding
tubing in place ensuring it is of appropriate
length. Do not kink tubing as this will impede
water flow. If necessary, loop tubing around
to avoid it being kinked.
Cut tubing straight with a utility knife or tube
cutter (for copper piping). (See Figure 2.)
5. Install faucet adapter fitting to faucet. This should be a snug fit. Do
not overtighten. (See Figure 3.)
Tools Needed:
Kit contains components necessary to connect 3/8” outlet tube to 1/2”
faucet fitting and 3/8” water supply. If you have any other size faucet
connection, you may need other parts for installation as required.
To Release Tubing
Push in grey
collet to release
tubing. With collet
held, pull tubing
straight out.
To Attach Tubing
Push tubing in as far as
it will go. Tubing must be
inserted past o-ring and
hit backstop. Pull tube
to ensure it is secured.
This filter can be used at any sink where water is used for drinking.
Hot
Cold
3/8" Tubing
Filter
Head/Bracket
#2 Phillips
Mounting
Screws
Filter
Cartridge
3/8"x1/2"
Faucet Adapter
3/8" T
3/8" Compression
Hex Nut
3/8" Ferrule
ube Insert
Parts and Materials Included:
Collet
Backstop
“Using Push-In Fittings”
Installation Requirements:
• Properly tighten all fittings to ensure a leak-free assembly.
• Install in a location that is not susceptible to freezing tempera-
tures as damage to the housing could occur.
• Install away from direct sunlight as prolonged exposure to light
can weaken plastic components.
• Some local codes may require the use of a licensed plumber or
certified installer when disrupting a potable water line. Determine
and follow any and all local codes and requirements.
• Allow a minimum of 2 1/2” clear space below unit to facilitate
filter change.
Figure 2
Figure 3
Figure 1
Figure 5
Figure 6
Correct
Incorrect
Inlet
Outlet to
Equipment
B
A
Figure 4
Gather the required tools before starting installation. Read and fol-
low the instructions provided with any tools listed here.