E series built-in single oven, Specifications, Installation specifications – Wolf Appliance Company SO30-2F/S User Manual
Page 2: Overall dimensions, Overall width 29, Overall height 27, Overall depth 23, Min inset width 30, Opening height 27, Min inset height 28
E Series Built-In Single Oven
Installation Notes
Wolf E Series built-in ovens may be used in
a standard installation, where the face trim
overlaps stiles and rails, or in a flush inset
installation with the front of the oven flush
with surrounding cabinetry.
Complete installation specifications can be
found on our website, wolfappliance.com.
Unit dimensions may vary by ±
1
/
8
".
27
3
/
16
"
(691)
OPENING
HEIGHT
28
1
/
2
"
(724)
OPENING WIDTH
5"
(127)
4"
(102)
24"
min (610)
OPENING DEPTH
E
E
E
E
33"
(838)
RECOMMENDED CABINET WIDTH
30"
min (762)
ELECTRICAL LOCATION
WITHIN OPENING
APPLIES ONLY TO
CABINETS DEEPER
THAN 24" (610)
Specifications
Overall Width
29
7
/
8
"
Overall Height
27
7
/
8
"
Overall Depth
23
3
/
4
"
Oven Door Clearance
22"
Oven Interior Capacity
4.5 cu ft
Oven Interior Dimensions
25" W x 16
1
/
2
" H x 19" D
Recommended Cabinet Width Standard 30"
Flush Inset 33"
Minimum Cabinet Depth
Standard 24"
Flush Inset 25"
Minimum Base Support
250 lbs
Opening Width
28
1
/
2
"
Min Inset Width
30
3
/
8
"
Opening Height
27
3
/
16
"
Min Inset Height
28
1
/
2
"
Electrical Requirements
240/208 V AC
60 Hz, 30 amp circuit
Electrical Rating
5.1 kW at 240 V
3.8 kW at 208 V
Shipping Weight
273 lbs
Installation
Specifications
Standard Installation
Overall Dimensions
IMPORTANT NOTE: Unless you are using cabinets
deeper than 24" (610) for a standard installation or
25" (635) for a flush inset installation, it is recom-
mended that the electrical supply be placed in an
adjacent cabinet within reach of the conduit.
Choose the location shown in the illustrations that
best suits your installation.
23
3
/
4
"
(603)
BEHIND FRAME
27
7
/
8
"
(708)
28
1
/
4
"
(718)
29
7
/
8
"
(759)
23
3
/
4
"
(603)
INSTALLER
SUPPLIED CABLE
CHANNEL
OPEN OVEN DOOR
TOP VIEW
22"
(559)
1
1
/
4
"
(32)
1"
(25)
1
7
/
8
"
(48)
1
7
/
8
"
(48)
RIGHT SIDE VIEW
27
1
/
16
"
(687)
29
7
/
8
"
(759)
2
5
/
8
"
(67)
27
3
/
16
"
(691)
OPENING
HEIGHT
28
1
/
2
"
min
(724)
FLUSH
INSET
HEIGHT
30
3
/
8
"
min
(772)
FLUSH INSET WIDTH
28
1
/
2
"
(724)
OPENING WIDTH
5"
(127)
4"
(102)
E
E
E
E
36"
(914)
RECOMMENDED CABINET WIDTH
33"
min (838)
24"
min
(610)
OPENING
DEPTH
1"
(25)
25"
min
(635)
FLUSH
INSET
DEPTH
7
/
16
"
(11)
7
/
8
"
(22)
ELECTRICAL LOCATION
WITHIN OPENING
APPLIES ONLY TO
CABINETS DEEPER
THAN 25" (635)
SIDE VIEW
TOP VIEW
Flush Inset
Installation
Dimensions in
parentheses are in
millimeters unless
otherwise specified.