SERVICE

HOW TO REMOVE AN OBJECT

FROM THE AIR INTAKE

WARNING:

Stop the unit and

disconnect from the power source be-

fore opening the inlet cover. The mo-

tor must be stopped and the impeller

blades no longer turning to avoid seri-

ous injury from the rotating blades.
S

While holding the inlet cover open, re-

move the vacuum tubes. The inlet cov-

er must be held open through all re-

maining steps.

S

Carefully reach into the vacuum open-

ing and clear out the air intake area.

Clear all debris from impeller.

S

Inspect the impeller for cracks. If

cracked or damaged, do not use the

unit. Have parts replaced by your autho-

rized service dealer. Do not attempt to

replace them yourself.

STORAGE

WARNING:

Perform the follow-

ing steps after each use:
S

Stop unit and disconnect from the pow-

er source.

S

Allow motor to cool before storing or

transporting.

S

Store unit with all guards in place. Posi-

tion unit so that any sharp object cannot

accidentally cause injury.

S

Store unit unplugged, well out of the

reach of children.

SEASONAL STORAGE

Prepare unit for storage at the end of

the season or if it will not be used for

30 days or more.

If your blower is to be stored for a period

of time:
S

Stop unit and disconnect from the pow-

er source.

S

Clean the entire unit before lengthy stor-

age.

S

Open inlet cover and clean any dirt,

grass, or debris that has collected. In-

spect the blower and all tubes. Close

and make sure the cover is latched.

S

Clean air vents and air inlet of debris.

S

Store your unit and extension cord in a

well ventilated area and covered, if pos-

sible, to prevent dust and dirt accumula-

tion. Do not cover with plastic. Plastic

cannot breathe and may cause con-

densation and eventual rust or corro-

sion.

S

Check entire unit for loose screws. Re-

place any damaged, worn, or broken

parts.

TROUBLESHOOTING TABLE

SYMPTOM

CAUSE

REMEDY

Unit fails to

operate.

1. Switch in the

OFF

position.

2. Extension cord discon--

nected.

3. Circuit breaker tripped, or

fuse blown.

4. Mechanical failure

1. Slide switch to

ON

position.

2. Reconnect extension cord.

3. Reset circuit breaker or

fuse.

4. Contact your authorized

service dealer.

Unit

vibrates

abnormally.

1. Mechanical failure

1. Contact your authorized

service dealer.

Impeller will

not turn

freely.

1. Debris in air intake area.

2. Mechanical failure.

1. Clean unit. Remove any

debris.

2. Contact your authorized

service dealer.

WARNING:

Always stop unit and disconnect from the power source before

performing all of the recommended remedies below except remedies that re-

quire unit to be operating.