White Rodgers 7904 User Manual

Page 3

background image

3

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 9. Typical wiring diagram for

heat pump with cool active reversing valve

TRANSFORMER

Reversing

Valve*

RC

O

B

JUMPER

WIRE

Compressor

Contactor

JUMPER

WIRE

* Reversing valve is energized when the
system switch is in the COOL position

Fan

Relay

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 8. Typical wiring diagram for

heat/cool, 5-wire, two-transformer systems

HEATING TRANSFORMER

Heating

System

Fan

Relay

Cooling
System

RC

24 VAC

120 VAC

Hot

Neutral

COOLING TRANSFORMER

O

B

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 7. Typical wiring diagram for

heat/cool, 4-wire, single transformer systems

TRANSFORMER

Heating

System

Fan

Relay

Cooling
System

RC

JUMPER

WIRE

RED jumper wire (provided
with thermostat) must be
connected between thermo-
stat's RH and RC terminals
for proper thermostat oper-
ation with this system.

NOTE

O

B

R

W

B

W

R

Thermostat

3-wire Series 10

Primary Control

(located at furnace)

Add jumper wire

(not provided with thermostat)

Figure 4. Typical wiring diagram for

3-wire SERIES 10 heating systems

Furnace

Jumper wire must be
added between R and B
terminals on the primary
control (jumper wire not
provided with thermostat).

NOTE

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 5. Typical wiring diagram for

heat only, 3-wire, single transformer systems

TRANSFORMER

Heating

System

Fan

Relay

Y

RC

JUMPER

WIRE

RED jumper wire (provided
with thermostat) must be
connected between thermo-
stat's RH and RC terminals
for proper thermostat oper-
ation with this system.

NOTE

O

B

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 10. Typical wiring diagram for

heat pump with heat active reversing valve

TRANSFORMER

Reversing

Valve*

RC

O

B

JUMPER

WIRE

Compressor

Contactor

JUMPER

WIRE

* Reversing valve is energized when the
system switch is in the HEAT position

Fan

Relay

RH

Y

THERMOSTAT

SYSTEM

G

W

Figure 3. Typical wiring diagram for heating only,

2-wire, single transformer systems or millivolt systems

Heating

System

RC

O

B

24 VAC Transformer

or

Thermopile

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 6. Typical wiring diagram for

cool only, 3-wire, single transformer systems

Cooling
System

Fan

Relay

RC

O

B