CHECK THERMOSTAT OPERATION

If at any time during testing your system does not operate
properly, contact a qualified serviceperson.

Fan Operation

If your system does not have a G terminal connection, skip to
Heating System.

1. Turn on power to the system.

2. Move FAN switch to ON position. The blower should begin

to operate.

RH

Y

THERMOSTAT

SYSTEM

G

W

Figure 3. Typical wiring diagram for heating only,

2-wire, single transformer systems or millivolt systems

Heating

System

RC

O

B

24 VAC Transformer

or

Thermopile

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 7. Typical wiring diagram for

heat/cool, 4-wire, single transformer systems

TRANSFORMER

Heating

System

Fan

Relay

Cooling
System

RC

JUMPER

WIRE

RED jumper wire (provided
with thermostat) must be
connected between thermo-
stat's RH and RC terminals
for proper thermostat oper-
ation with this system.

NOTE

O

B

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 9. Typical wiring diagram for

heat pump with cool active reversing valve

TRANSFORMER

Reversing

Valve*

RC

O

B

JUMPER

WIRE

Compressor

Contactor

JUMPER

WIRE

* Reversing valve is energized when the
system switch is in the COOL position

Fan

Relay

R

W

B

W

R

Thermostat

3-wire Series 10

Primary Control

(located at furnace)

Add jumper wire

(not provided with thermostat)

Figure 4. Typical wiring diagram for

3-wire SERIES 10 heating systems

Furnace

Jumper wire must be
added between R and B
terminals on the primary
control (jumper wire not
provided with thermostat).

NOTE

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 5. Typical wiring diagram for

heat only, 3-wire, single transformer systems

TRANSFORMER

Heating

System

Fan

Relay

Y

RC

JUMPER

WIRE

RED jumper wire (provided
with thermostat) must be
connected between thermo-
stat's RH and RC terminals
for proper thermostat oper-
ation with this system.

NOTE

O

B

RH

Y

24 VAC

120 VAC

Hot

Neutral

TRANSFORMER

THERMOSTAT

SYSTEM

G

W

Figure 6. Typical wiring diagram for

cool only, 3-wire, single transformer systems

Cooling
System

Fan

Relay

RC

O

B

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 8. Typical wiring diagram for

heat/cool, 5-wire, two-transformer systems

HEATING TRANSFORMER

Heating

System

Fan

Relay

Cooling
System

RC

24 VAC

120 VAC

Hot

Neutral

COOLING TRANSFORMER

O

B

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 10. Typical wiring diagram for

heat pump with heat active reversing valve

TRANSFORMER

Reversing

Valve*

RC

O

B

JUMPER

WIRE

Compressor

Contactor

JUMPER

WIRE

* Reversing valve is energized when the
system switch is in the HEAT position

Fan

Relay

3. Move FAN switch to AUTO position. The blower should stop

immediately.

Heating System

1. Move SYSTEM switch to HEAT position. If the heating

system has a standing pilot, be sure to light it.

2. Press

to adjust thermostat setting above room tempera-

ture. The heating system should begin to operate.

3. Press

to adjust temperature setting below room tempera-

ture. The heating system should stop operating.