Heating system, Cooling system, Caution – White Rodgers 1F87-251 User Manual

Page 3

background image

3

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 5. Typical wiring diagram for

heat/cool, 5-wire, two-transformer systems

HEATING TRANSFORME R

(Class II Current Limited)

Heating

System

Fan

Relay

Cooling
System

RC

24 VAC

120 VAC

Hot

Neutral

COOLING TRANSFORMER

(Class II Current Limited)

O

B

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 4. Typical wiring diagram for

heat/cool, 4-wire, single transformer systems

Heating

System

Fan

Relay

Cooling
System

RC

JUMPER

WIRE

O

B

RED jumper wire (provided with thermostat) must be
connected between thermostat RH and RC terminals
for proper thermostat operation with this system.

NOTE

TRANSFORMER

(Class II Current Limited)

RH

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 2. Typical wiring diagram for

heat only, 3-wire, single transformer systems

TRANSFORMER

(Class II Current Limited)

Heating

System

Fan

Relay

Y

RC

JUMPER

WIRE

O

B

For 2-wire Heat only,
attach to RH and W

NOTE

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 7. Typical wiring diagram for heat pump

with reversing valve energized in HEAT

Reversing

Valve*

RC

O

B

JUMPER

WIRE

Compressor

Contactor

JUMPER

WIRE

* Reversing valve is energized when the
system switch is in the HEAT position

Fan

Relay

TRANSFORMER

(Class II Current Limited)

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 3. Typical wiring diagram for

cool only, 3-wire, single transformer systems

Cooling
System

Fan

Relay

RC

O

B

JUMPER

WIRE

TRANSFORMER

(Class II Current Limited)

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 6. Typical wiring diagram for heat pump

with reversing valve energized in COOL

Reversing

Valve*

RC

O

B

JUMPER

WIRE

Compressor

Contactor

JUMPER

WIRE

* Reversing valve is energized when the
system switch is in the COOL position

Fan

Relay

TRANSFORMER

(Class II Current Limited)

Heating System

1. Move SYSTEM switch to HEAT position. If the heating

system has a standing pilot, be sure to light it.

2. Press

to adjust thermostat setting above room tempera-

ture. The heating system should begin to operate.

3. Press

to adjust temperature setting below room tem-

perature. The heating system should stop operating.

CAUTION

!

Cooling System

To prevent compressor and/or property damage, if the
outdoor temperature is below 50°F, DO NOT operate
the cooling system.

1. Move SYSTEM switch to COOL position.

2. Press

to adjust thermostat setting below room tem-

perature. The blower should come on immediately on high
speed, followed by cold air circulation

3. Press

to adjust temperature setting above room tem-

perature. The cooling system should stop operating.