VENTILATION
ƽWARNING: Air holes must be provided in the structure at the
top and bottom to provide ventilation in the event of a gas leak.
Air holes can be located in a low visibility area and should be protected by screening
material to prevent rodents and insects from entering the structure. Air holes will also help
dry moisture.
Summit
®
Built-In cabinet vents are available from your dealer or call Customer Service at
1-800-446-1071.
Note: These drawings are only a reference.
•
Cross ventilation must be incorporated in the supporting structure. We recommend
a minimum of 100 square inches (254 square cm )of venting per side.
•
Vents should be on two sides of the structure.
•
The above drawings are for reference only.
•
Location of the vents should be from the center, outward.
•
Locate the vents at both the bottom of the structure and at the top of the structure.
•
The bottom vents should be as close to ground level as possible. Make sure the
vent area is not blocked by interior supports of the structure.
•
We recommend vents with screens.
•
Access doors to the structure are not considered vents.
•
Clean the vents periodically.
ƽ DANGER: Failure to follow recommended minimum venting
instructions can cause gas to collect in the structure in the
event of a gas leak. This may result in a fi re or an explosion
which can cause serious bodily injury or death, and damage to
property.
GAS SUPPLY