INSTALLATION

SELECTING THE BLOWER OFF DELAY

In the heating mode, the blower off delay can be selected
to obtain a 90, 120 or 150 seconds period. This can be
accomplished by changing the position of a plastic jumper
located on the ignition control. See the drawing below for
the location of this jumper.

The control is factory set to give a (150) second blower off
delay. See drawing below for the jumper position for all
available settings:

Notes:

If the jumper is removed, the control will default to a
(150) second blower off delay in the heating mode.

The blower on time in the heating mode is (30)
seconds and is non-adjustable.

The blower on time in the cooling mode is (5) seconds
and is non-adjustable.

The blower off delay in the cooling mode is (60)
seconds and is non-adjustable.

Caution is to be exercised not to bend the metal pins
when changing the time delay from the factory setting.

DIAGNOSTIC FEATURES

The 50T35-743 control continuously monitors its own
operation and the operation of the system. If a fault occurs,
the LED will indicate a fault code as shown below. If the
fault is internal to the control, the light will stay off. In
this case, the entire control should be replaced, as the
control is not field-repairable
.

If the sensed failure is in the system (external to the
control), the LED will flash in the following flash-pause
sequences to indicate failure status (each flash will last
approximately 0.25 seconds, and each pause will last
approximately 2 seconds).

Monitored

LED

Condition

During

Action

Solid On

Normal

All Times

None required

1 Flash

Ignition retries

Heating

Gas Valve “Off”

exceeded

Demand

Circulator

“Delay Off”

Inducer “Off”

2 Flashes

PSW Stuck

Heating

All Outputs

Closed

Demand

“Off” except circ

Only

cool speed in

response to a

call for fan/cool

3 Flashes

PSW Stuck

Heating

All Outputs

Open

Demand

“Off” except circ

Only

cool speed in

response to a

call for fan/cool

4 Flashes

Limit Switch

Heating

Gas Valve “Off”

Open

Demand

Circulator “On”

Only

Inducer “On”

5 Flashes

Improper

All Times

Gas Valve “Off”

Flame

Circulator “On”

Inducer “On”

Rapid

Improper

Power-up Gas Valve “Off”

Flashing

Polarity

Circulator “Off”

Inducer “Off”

Twinning

All other

Gas Valve “Off”

Fault

times

Circulator “Off”

Inducer “Off”

Off

Internal error

All Times

Gas Valve “Off”

detected

Circulator “Off”

Inducer “Off”

BLOWER
TIME OFF
JUMPER

90

120

150

STATUS

TWIN

W

G

R

STATUS

90

120

150

90

120

150

90

120

150

JUMPER SET

STATUS

JUMPER SET

STATUS

JUMPER SET

FOR 90 SEC.

FOR 120 SEC.

FOR 150 SEC.