Query status of the digital input – Vivotek FD6111V User Manual
Page 83
![background image](/manuals/220872/83/background.png)
- 79 -
www.vivotek.com
T: 886-2-82455282
F: 886-2-82455532
Syntax:
http://<servername>/cgi-bin/setdo.cgi?do1=
[&do3=
Where state is H, L. H means NC (normal close) connected with COMMON and L
means NO (normal open) connected with COMMON. The number of DO dependents
on the server type.
parameter Value
description
H – NC connected with COMMON
do
L – NO connected with COMMON
return
Redirect to the page
parameter is assigned. The
be a full URL path or relative path according the
the current path. If you omit this parameter, it
will redirect to an empty page.
Example: Drive the digital output 1 to high and redirect to an empty page
http://myserver/cgi-bin/setdo.cgi?do1=H
Query status of the digital input
Note: This request requires the privilege of I/O access control.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/getdi.cgi?[di1][&di2][&di3][&di4]
If no parameter is specified, all the status of digital input will be returned.
Return: