Vivotek IP7142 User Manual
Page 86

VIVOTEK - A Leading Provider of Multimedia Communication Solutions
86 - User's Manual
Drive the digital output
Note: This request requires the privilege of viewer.
Method: GET/POST
Syntax:
http://
[&return=
Where state is 0, 1. “0” means inactive or normal state while “1” means active or triggered state.
Parameter
Value
Description
do
0,
1
0 => inactive, normal state
1 => active, triggered state
return
Redirect to the page
is assigned. The
relative path according the current path. If you omit this
parameter, it will redirect to an empty page.
Example: Drive the digital output 1 to triggered state and redirect to an empty page
http://myserver/cgi-bin/dido/setdo.cgi?do1=1
Query status of the digital input
Note: This request requires the privilege of viewer.
Method: GET/POST
Syntax:
http://
If no parameter is specified, all the status of digital input will be returned.
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/plain\r\n
Content-Length:
\r\n
[di0=
[di1=
[di2=
[di3=
where
Example: Query the status of digital input 1