User's Manual - 121

localityname

string[128]

6/6

the locality name in certificate information

organizationname

string[64]

6/6

organization naem in certificate information

unit

string[32]

6/6

organizational unit name in certificate

information

commonname

string[64]

6/6

common name in certificate information

validdays

0 ~ 9999

6/6

certificatation valid period

Drive the digital output

Note: This request requires the privilege of viewer.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/dido/setdo.cgi?do0=[&do1=][&do2=]

[&do3=][&return=]

Where state is 0, 1. “0” means inactive or normal state while “1” means active or triggered state.

PARAMETER

VALUE

DESCRIPTION

0 – inactive, normal state

do

0, 1

1 – active, triggered state

return

Redirect to the page after the parameter is

assigned. The can be a full URL path or relative

path according the current path. If you omit this parameter, it

will redirect to an empty page.

Example: Drive the digital output 1 to triggered state and redirect to an empty page

http://myserver/cgi-bin/dido/setdo.cgi?do0=1

Query status of the digital input

Note: This request requires the privilege of viewer.

Method: GET/POST

Syntax: