Drive the digital output, Query status of the digital input – Vivotek IP7139 User Manual
Page 99

- 89 -
www.vivotek.com
Drive the digital output
Note: This request requires the privilege of viewer.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/setdo.cgi?do1=
[&do3=
Where state is 0, 1. “0” means inactive or normal state while “1” means active or
triggered state.
PARAMETER
VALUE
DESCRIPTION
0 – inactive, normal state
do
0, 1
1 – active, triggered state
return
Redirect to the page
parameter is assigned. The
a full URL path or relative path according the the
current path. If you omit this parameter, it will
redirect to an empty page.
Example: Drive the digital output 1 to triggered state and redirect to an empty page
http://myserver/cgi-bin/dido/setdo.cgi?do1=
1
Query status of the digital input
Note: This request requires the privilege of viewer.
Method: GET/POST
Syntax:
98 - User's Manual