Vector VEC1098A User Manual
Page 5
5
OPERATING INSTRUCTIONS
Ensure that all installation and operating instructions and safety
precautions are understood and carefully followed by anyone
installing or using the charger. Follow the steps outlined in “Important
Safety Instructions” at the front of this manual.
Battery Voltage Selection
Before proceeding with any operation, the user must select the voltage of battery on
the Battery Voltage Selector Switch (see the Control Panel diagram on page 3).
Charge Rate Selection
After charger clamps are correctly connected, plug the charger into a 120 volt AC
outlet and the charger will show a circulating pattern on the Digital Display, indicating
power has been applied. Select the proper charge current rate based on battery size.
Press the 4/15/30/50 AMP button and the charger will begin charging at 4 amps.
Pressing the 4/15/30/50 AMP button again will advance the charge rate to 15
amps, again to 30 amps, and again to 50 amps. Pressing the switch again will turn
OFF the charger output and the display will show “000”.
Note:
The only time the selected charge rate does not display at the full selected rate
is when the battery is nearly full and charging at either step two or three.
The display will show a reduced charge rate. To return to 4A, press the
4/15/30/50 AMP button. When the battery is fully charged, “FUL” shows on the
Digital Display.
WARNING
If Digital Display shows “F02”, the connection to the battery terminals
is bad. Follow the steps outlined in “Important Safety Instructions” at
the front of this manual to disconnect, clean battery terminals, then
reconnect.
If Digital Display shows “F06”, the RED (POSITIVE) and BLACK
(NEGATIVE) clamps are incorrectly connected to battery terminals.
Follow the steps outlined in “Important Safety Instructions” at the
front of this manual to disconnect, then reconnect in correct polarity.
Charging the Battery
1. Press Battery Type selector until desired battery type LED lights.
Note:
The default selection is “GEL” type battery.
2. Press 4/15/30/50 AMP button to begin charging at the 4 amp rate; the unit
sounds a beep and the charging current LED lights. The charger starts charging
at 4 amp rate automatically if 4/15/30/50 AMP button is not pressed within
3 minutes after applying AC power.
If the Display on the charger varies between “F03” and the amp rate, the battery
is sulfated and the charger is trying to give it some charge. If after approximately
2 hours the display just shows “F03”, then the battery will not charge.
Charger occasionally sounds a beep and displays “0.0” during self-test or
charging stage changes.
3. Pressing the 4/15/30/50 AMP button again advances charging rate to 15
amps, pressing once more advances charging rate to 30 amps, and again to 50
amps. (Pressing the button again will turn OFF the charger output and the Display
will show “000”.) This selection and actual battery charge rate are monitored by
4
CONTROL PANEL LED INDICATORS:
WET — lights when battery type selector is on WET battery type.
GEL — lights when battery type selector is on GEL battery type.
AGM — lights when battery type selector is on AGM battery type.
Float Charge — lights when automatic charge monitoring is active. This feature
allows a battery to maintain its charge over long periods of non-use. If there is any
loss of power to the charger once power is restored, charger will automatically return
to the default settings. Battery selector type would be “GEL”.
Battery Voltage — lights when battery voltage is displayed.
Alternator Good — lights when load or not load checks show the alternator is
keeping up with the electrical load.
BUTTON (TO THE RIGHT OF LEDS):
Equalize — a recessed button used to start the equalization process.
AC POWER INDICATOR - When connected to an AC outlet, digital display shows circulating pattern to
indicate power is on. Disconnect charger after use.
FAULT CODES
OPERATION CODES
F01
F02
F03
F04
F05
F06
F07
000
FUL
INTERNAL SHORTED CELL BATTERY - Cannot be charged. Have battery checked by certified auto service center.
EXCESSIVE LOAD ON BATTERY WHILE CHARGING - Check load.
BAD BATTERY CONNECTION - Check battery connection.
BATTERY VOLTAGE TOO LOW TO ACCEPT CHARGE - Have battery checked by certified auto service center.
BATTERY RECONDITIONING - (The letters DES will display for the first 3 seconds.)
INTERNAL OPEN CELL - Have battery checked by certified auto service center.
SULFATED CONDITION - Battery needs to be reconditioned. See manual.
OVERHEATED CONDITION - Disconnect charger and allow to cool for 30 min., check for ample ventilation.
REVERSE POLARITY
ALTERNATOR OUTPUT IS OUT OF TYPICAL OPERATION RANGE
ALTERNATOR VOLTAGE CHECK
CHARGER STANDBY
BATTERY FULLY CHARGED
OVERTIME CONDITION - Battery will not accept a charge after 18 hours of continuous charging. Battery may have
internal damage. Have battery checked by certified auto center.
BATTERY CHARGE RATE IS SET TOO LOW - Set charger to higher charge rate. See manual.
VEC1098A_Manual_082606 8/26/06 12:56 PM Page 4