APPENDIX A - CHARGING TIMES

To calculate the approximate charging time required to fully charge a battery, it is necessary to determine

the specific gravity (or, percent of battery charge) using a hydrometer. Use this technique, if battery vent

caps can be removed. Check each cell. If there is one cell with a very low specific gravity compared to

the other cells, there is probably a shorted cell in the battery. Replace the battery.
The following chart converts hydrometer readings into percent of charge values.

Specific Gravity

Percent of Charge

Percent of Charge Needed

(Hydrometer Reading)

In Battery

By Battery

1.265 . . . . . . . . . . . . . . . . . . . . .100% . . . . . . . . . . . . . . . . . . . . . . . .0%
1.225 . . . . . . . . . . . . . . . . . . . . .75% . . . . . . . . . . . . . . . . . . . . . . . .25%
1.190 . . . . . . . . . . . . . . . . . . . . .50% . . . . . . . . . . . . . . . . . . . . . . . .50%
1.155 . . . . . . . . . . . . . . . . . . . . .25% . . . . . . . . . . . . . . . . . . . . . . . .75%
1.120 . . . . . . . . . . . . . . . . . . . . . .0% . . . . . . . . . . . . . . . . . . . . . . . .100%

Refer to the chart below for approximate charging times.
PERCENT OF CHARGE

75%

50%

25%

0%

2 AMPS/12 VOLTS

6.5 HRS

12 HRS

18 HRS

23 HRS

15 AMPS/12 VOLTS

1.5 HRS

2 HRS

3.0 HRS

3.5 HRS

15 AMPS/6 VOLTS

1.8 HRS

3.0 HRS

4.5 HRS

6HRS

The times shown in the chart above are approximate and refer to an average automotive battery. For smaller

batteries, the charge time should be adjusted using the formula shown below and adding 1 hour to the time

calculated.
To estimate charging time for a discharged battery, divide the AH rating of the battery by the charge rate

selected. This is the number of hours required to recharge the battery. For example, a 50 AH (12 volt)

battery is discharged to 10 volts. How long should it be charged at the 15 Amp rate? Divide the 50 AH by

15 AH. The answer is approximately 3.5 hours. A six-volt battery is considered discharged when it reaches

5.0 VDC. Always round up the charge time by 25% to ensure full charge. In most cases, battery recharge

times will vary depending on the age and condition of the battery. Smaller batteries should be charged at

the lower rate (2 Amps) and add an extra hour to charge time.

APPENDIX B - SPECIFICATIONS

Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.75” (14.6 cm)
Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.25” (26.1 cm)
Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.25” (15.9 cm)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17.7 lbs, 8.0 kgs.
Internal protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .self-resetting breaker
Reverse Polarity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .indicator LED
Charging complete (12 V FULL) . . . . . . . . . . . . . . . . . . . . . . . . .auto shut-off LED for 12 volt
Convenience features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Handle
Power Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120V AC, 60 Hz, 2.8 Amperes