Victory Refrigeration V-Series User Manual
Page 13

3.
Hinges and Lock Keeper
a.
Refer to Figure 2-3. To remove the hinge base from
the cabinet fascia, unscrew the three phillips type
machine screws.
Figure 2-3
b. To remove lock keeper (“D” shaped metal stamping
for lock bolt), use a 5/16” open end wrench. Remove
the two #10-32 screws attaching keeper to fascia.
Reverse procedure to reinstall. Refer to Figure 2-4.
Figure 2-4
Lock Keeper
D. Rehingeability (One & Two Section Long Door
Cabinet)
1.
Remove door from cabinet by opening it about 90
°
and lifting it from it’s supporting brackets (as
mentioned on page 7).
2.
Carefully pry the hinge barrel cover from hinge barrel
(Fig 2-5).
Figure 2-5
3.
Remove hinge barrels from door, turn them upside
down and replace on door (Figure 2-6).
Figure 2-6