Viking VCWB300 User Manual
Page 15
![background image](/manuals/218547/15/background.png)
General Information:
Approved Board Certification
CSA – UL
Suction
0.256” + 0.005” / - 0.003”
Discharge
0.194” + 0.003” / - 0.003”
Process
0.256” + 0.005” / - 0.003”
Mechanical Data:
Low Starting Torque (LST)
Lubricant Charge
6.76 fl. Oz.
Lubricant type
ESTER
Lubricant Viscosity @ 40
° C
ISO 22
Weight (with Oil Charge)
15.43 lbs.
Nitrogen Charge
2.84 to 4.27 psig.
Application:
Evaporating Temperature range
14
°F to -31°F
Refrigerant R134a
Refrigerant Charge
7.5 oz.
Expanding Device
Capillary Tube
Compressor Cooling
Operating Range (60Hz)
LBP
32
° C Ambient Temp. 98 to 140V
LBP
43
° C Ambient Temp 98 to 140V
Maximum Condensing Pressures
Operating
230
psig.
Peak
293
psig.
Electrical Data:
Normal Voltage
115VAC – 60Hz
Start Winding Resistance
21.20
Ω (at 77°F) ± 8%
Run Winding Resistance
7.90
Ω (at 77°F) ± 8%
Locked Rotor Amperage (60Hz)
9.80 Amps.
Full Load Amperage (60Hz)
1.20 Amps
Check Point Data:
Test Conditions: @115V - 60Hz (Evaporator
Temp.-10
°F / Condensing
Temp.130
°F)
Cooling Capacity
± 5%
275 Btu/h
81 Watts
Power Consumption
± 5%
75 Watts
Current Consumption
± 5%
0.98 Amps
16