Vivotek v User Manual
Page 76
![background image](/manuals/218355/76/background.png)
www.vivotek.com
T: 886-2-82455282
F: 886-2-82455532
Preview
Apply the parameter of image but
not save
Restore
Restore the last saved image
parameters
mode
(w)
Save
Directly save the adjust image
parameters
Group: Motion
NAME VALUE DESCRIPTION
0
disable motion detection
enabled
(r/w)
1
enable motion detection
0
disable motion window #1
winenabled_<1~3
>
(r/w)
1
enable motion window #1
winname_<1~3>
(r/w)
name of motion window #1
winleft_<1~3>
(r/w)
0 ~ 352 for CCD
0 ~ 320 for CMOS
Left coordinate of window position.
<0>
wintop_<1~3>
(r/w)
0 ~ 288 for PAL
0 ~ 240 for
NTSC & CMOS
Top coordinate of window position.
<0>
winwidth_<1~3>
(r/w)
0 ~ 352 for CCD
0 ~ 320 for CMOS
Width of motion detection window.
<0>
winheight_<1~3>
(r/w)
0 ~ 288 for PAL
0 ~ 240 for
NTSC & CMOS
Height of motion detection window.
<0>
winobjsize_<1~3>
(r/w)
0 ~ 100
Percent of motion detection window
<0>
winsensitivity_<1~
3>
(r/w)
0
~
100
Sensitivity of motion detection
window