NATURAL GAS RESIDENTIAL HEATERS

®

For more information, visit www.desatech.com

OPERATING
HEATER

TO TURN OFF GAS

TO APPLIANCE

Figure 22 - Pilot

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• If control knob does not pop up

when released, contact a qualified
service person or gas supplier for
repairs.

Note:

If pilot goes out, repeat steps

3 through 7. This heater has a safety
interlock system. Wait one (1) minute
before lighting pilot again.

8.

Push knob in slightly and turn con-
trol knob counterclockwise
to desired heating level. The main
burner should light. Set control knob
to any heat level between HI and LO.

LIGHTING

INSTRUCTIONS

Figure 21 - Control Knob In The OFF
Position

PILOT

LO

OFF

HI

IGNITOR

Control Knob

Ignitor Button

1.

STOP! Read the safety information
in column 1.

2.

Make sure equipment shutoff valve
is fully open.

3.

Turn control knob clockwise
to the OFF position.

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation, column 1. If you don’t
smell gas, go to the next step.

5.

Turn control knob counterclockwise

to PILOT position. Press in

control knob for five (5) seconds (see
Figure 21).

Note:

You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.

6.

With control knob pressed in, push
down and release ignitor button.
This will light pilot. The pilot is at-
tached to the front of burner. If
needed, keep pressing ignitor but-
ton until pilot lights.

Note:

If pilot does not stay lit, refer

to Troubleshooting, pages 16 through
18. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot with
match. To light pilot with match, see
Manual Lighting Procedure
, page 15.

FOR YOUR SAFETY

READ BEFORE

LIGHTING

Shutting Off Heater

1.

Turn control knob clockwise
to the OFF position.

Note:

Knob must be depressed slightly.

2.

Turn off all electric power to the ap-
pliance if service is to be performed.

Shutting Off Burner Only (pilot
stays lit)

Turn control knob clockwise

to

the PILOT position.

Note:

Knob must be depressed slightly.

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

CAUTION: Do not try to adjust

heating levels by using the equip-
ment shutoff valve.

Pilot Burner

Thermocouple

Ignitor Electrode