beautypg.com

Specifications – United States Stove Company 5500XL User Manual

Page 4

background image

4

USSC

Specifications

Heat Output

1

48,000 BTU/hr.

Heating Capacity

2

800 - 2,000 sq. ft.

Fuel Burn Rate

3

2.0 - 6.0 lbs./hr.

Burn Time (lowest setting)

5500 - 60 hrs.

5500XL - 160 hrs.

Hopper Capacity

5500 - 150 lbs. 5500XL - 320 lbs.

Heating Specifications

5500

5500XL

Height

34 in.

47 1/4 in.

Width

26 in.

26 hrs.

Depth

25 in.

25 hrs.

Weight

250 lbs.

275 hrs.

Dimensions

1

BTU output will vary depending on the quality of fuel. Use PFI listed fuels for the best results.

2

Heating capacity will vary depending on floor plan layout of your home, degree of insulation, and the outside temperature.

3

Pellet size may effect the actual rate of fuel feed and burn times. Fuel feed rates may vary by as much as 20%. Use PFI listed fuel for best results.

Electrical Rating

110-120 volts, 60 HZ, 3.0 Amps

Watts (operational)

175 (approx.)

Watts (igniter running)

425 (approx.)

Electrical Specifications

FUEL CONSIDERATIONS

Your King/Ashley stove is designed to burn premium hardwood pellets that comply with Association of Pellet Fuel
Industries standards. (Minimum of 40 lbs density per cubic ft, 1/4” to 5/16” diameter, length no greater than 1.5”, not
less than 8,200 BTU/lb, moisture under 8% by weight, ash under 1% by weight, and salt under 300 parts per million).
Pellets that are soft, contain excessive amounts of loose sawdust, have been, or are wet, will result in reduced
performance.

SAFETY AND EPA COMPLIANCE

Your King/Ashley stove has been safety tested and listed to ASTM E 1509, (UM) 84-HUD by OMNI-Test
Laboratories, Inc. Beaverton, Oregon, USA. It is also exempt from EPA Phase II requirements.