Interior lighting, Electronic control panel – U-Line 2115R User Manual
Page 8
8
2115R, 2175R
Interior Lighting
The LIGHT icon (Figure 3, 5) on the control panel is used
to control an additional lighting function. The blackout/
Sabbath mode (not Star K certified) will turn the interior
light and display (Figure 3, 3) off for a preset 36-hour
period.
To access the blackout/Sabbath mode (not Star K
certified):
1. Touch and hold the LIGHT icon (Figure 3, 5) for ten
seconds and release (the °F symbol will flash briefly at
the end of the five second period).
2. The interior light and control display (Figure 3, 3) will
go dark for the next 36 hours.
NOTE: Although the display will not be visible, the
temperature controls in the unit remain active, and the
interior temperature will be maintained.
3. To exit the blackout/Sabbath mode (not Star K
certified) before the 36-hour period, repeat Step 1.
Electronic Control Panel
Figure 5
The electronic control with digital display (Figure 5) is
configured to show a single temperature continuously.
This set-point temperature is a base number used by the
controller to maintain the temperature zone in your unit.
The factory default set-point is 38°F. This set-point
temperature is used as a gauge if further temperature
adjustments are required.
Temperature Display Selection
U-Line products supplied for 110 VAC operation have
temperatures displayed in a default Fahrenheit (°F)
configuration (Figure 5, 3). Models supplied for 220 VAC
operation have temperatures displayed in a default
Celsius (°C) configuration.
The display can easily be adjusted for either type of
temperature display. Press and hold the LIGHT icon
(Figure 5, 5) and within five seconds press the COOLER
icon (Figure 5, 4) three times to change the display as
desired.
Temperature Display
To display the interior temperature:
1. Touch and hold the WARMER icon (Figure 5, 2) for
approximately five seconds and release when the °F
symbol in the display (Figure 5, 3) begins to flash.
2. The display (Figure 5, 3) will indicate the actual
refrigerator temperature.
3. After approximately 10 seconds, the set-point
temperature will return to the display.
Factors which affect the internal temperatures of the
cabinet include:
• Temperature setting.
• Ambient temperature where installed.
• Number of times and length of time the door is
opened and closed.
• Installation in direct sunlight or near a heat source.
Adjusting Temperature
IMPORTANT
IMPORTANT
Adjust the set-point temperature in single
increments, and wait 24 hours for the temperature
to stabilize before rechecking.
Figure 6
To adjust the set-point temperature:
1. Press and release either the WARMER (Figure 6, 2) or
COOLER (Figure 6, 4) icon to put the controller in the
SET TEMPERATURE mode. The °F symbol (Figure 6, 3)
will begin to flash.
NOTE: If no further action is taken, this mode will self
cancel in five seconds, and the original set-point
temperature will be displayed.
2. While the °F symbol is flashing, press the WARMER or
COOLER icon as required to adjust the set-point
temperature.
3. The change will be set five seconds after adjusting the
temperature and the new set-point temperature will be
displayed.
1
2
3
5
4
ULIN_0058_A
1
2
3
5
4
ULIN_0058_A