USSC
Installation
CLEARANCES
Your Forester stove has been tested and listed for installation in residential, mobile home, and alcove applications in
accordance with the clearances given in FIGURES 3-4 and TABLE 1.
NOTE: Distance “D” on the left-hand side of your Forester stove may need to be greater than the minimum
required clearance for suitable access to the control panel.
FIGURE 3
SIDEWALL / CORNER
MINIMUM CLEARANCES
FIGURE 4
MINIMUM ALCOVE CLEARANCES
PARALLEL
A - Backwall to heater
8.00” / 203mm
B - Backwall to flue
1.00” / 25mm
C - Sidewall to flue
7.50” / 191mm
D - Sidewall to edge of unit
4.00” / 100mm
CORNER
E - Adjacent wall to unit
2.00” / 50mm
ALCOVE
F - Alcove depth
25.00” / 635mm
G - Alcove Hieght
47.00”/ 1194mm
Alcove Width
26.50” / 673mm
TABLE 1
MINIMUM CLEARANCES
(inches/mm)