beautypg.com

Universal Security Instruments 3885 User Manual

Page 9

background image

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:

-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.

CAUTION (AS REQUIRED BY THE CALIFORNIA STATE FIRE MARSHAL)

"Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the
household as follows. A smoke alarm installed in each separate sleeping area (in the vicinity of, but outside of the
bedrooms), and heat or smoke detectors in the living rooms, dining rooms, bedrooms, kitchens, hallways, attics, furnace
rooms, closets, utility and storage rooms, basements and attached garages.

THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY,

UL217 BY UNDERWRITERS LABORATORIES, INC.

Page 9

Blinks On once

approx every

40-45 seconds

Stays On

AC Power is present.

Off

Off

AC Power is not present. Check the breaker or fuse
box for power. If the breaker or fuse box looks normal,
call a licensed electrician for assistance.

OPERATIONAL SUMMARY

Silent

Silent

Blinks On

approx every

2 seconds

Stays On

Nuisance Alarm - If there is no hazard present, verify
the alarm is mounted in the correct location (see User's
Manual, "AVOID THESE LOCATIONS" section). Reset
alarm as instructed below.

Horn does not

sound when other

alarms are active

or horn does not

sound when

inter-connected

alarm's test

button is pressed

Blinks On once

approx every

40-45 seconds

Stays On

or Off

Press and hold the smoke alarm Test/Silence button
for at least 5 seconds. If still no alarm, turn off AC Power
at the circuit breaker or fuse box and disconnect the
alarm from the mounting bracket and make sure the
connector plug is securely attached on units that did
not alarm. If still no alarm, have a licensed electrician
check to see if the yellow wire is connected to the neutral
wire.

3 Beeps,

2 second pause,

Repeat

Blinks On

approx every

2 seconds

Stays On

Originating Smoke Alarm - If hazard is identified, please
take all precautions if an alarm sounds by calling an
Emergency Service and getting out of the home.

3 Beeps,

2 second pause,

Repeat

Off

Stays On

Non-originating Smoke Alarm - Another interconnected
smoke alarm has sensed smoke, causing all
interconnected units to sound.

Blinks On once

approx every

40-45 seconds

(normal operation

mode) or Blinks on
once approx every

10 seconds

(silence mode)

Stays On

Stays On

To Reset the Alarm - Hold the Test/Silence button for 10
seconds. This will clear alarm origination and clear
Silence mode. Reset after each smoke alarm event.

Silent

3 Beeps,

2 second pause,

Repeat

3 Beeps,

2 second pause,

Repeat

Stays On

Silence Feature is activated by pressing and releasing
the Test/Silence button on the initiating alarm while in
alarm condition. Silence mode will last for approx 8-12
minutes.

Blinks On

approx every

2 seconds

Silent

(alarmed

previously)

CONDITION OF ALARM AUDIBLE & VISUAL SIGNALS BEFORE SOLUTION / RECOMMENDATION

SOLUTION / RECOMMENDATION

HORN

RED LED

GREEN LED

Blinks On once

approx every

40-45 seconds

(normal operation

mode) or Blinks on
once approx every

10 seconds

(silence mode)

QUICK FIND

®

Alarm Origination - In an interconnected

system, it is difficult to determine which alarm initiated
the alarms to sound. The

QUICK FIND

®

feature will

allow you to immediately locate the originating alarm
(once the alarms have stopped sounding). To initiate

QUICK FIND

®

, press the Test/Silence button on any

alarm; and, after releasing the button, the originating
alarm will continue to sound for approx 60 seconds.
Reset the originating alarm. NOTE: In a non-
interconnected installation, it is necessary to test each
alarm to determine the originating alarm.

Blinks On once

approx every

40-45 seconds

3 Chirps approx

every 40 seconds

after LED flashes

Stays On

Trouble/Service Alarm. Replace Alarm.

This manual is related to the following products: