Universal Security Instruments 976 User Manual

Page 8

background image

Page 8

THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY,

UL217 BY UNDERWRITERS LABORATORIES, INC.

Blinks On once

approx every

40-45 seconds

DC Power is present.

3 Beeps,

2 second pause,

Repeat

Blinks On approx

every 2 seconds

3 Beeps,

2 second pause,

Repeat

Blinks On approx

every 2 seconds

Blinks On once

approx every

40-45 seconds

(normal operation

mode) or Blinks on

once approx every

10 seconds

(silence mode)

Originating smoke alarm - If hazard is identified, please take
all precautions if an alarm sounds by calling an Emergency
Service and getting out of the home.

OPERATIONAL SUMMARY

Silent

Blinks On once

approx every

40-45 seconds

Silent

1 Chirp

approx.every

40 seconds

Low Battery - Check to make sure the battery activation pull-
tab has been completely removed, battery polarity is correct
and the battery terminals are making contact with the smoke
alarm contacts in the battery drawer. If chirp continues,
replace the 9V battery (see User's Manual for recommended
battery types).

To Reset the Alarm - Hold the Test/Silence button for 10
seconds, or temporarily remove (and then replace) the battery.
This will clear alarm origination and clear Silence mode. Reset
after each smoke alarm

event.

Nuisance Alarm - If there is no hazard present, verify the
alarm is mounted in the correct location (see User's Manual,
"AVOID THESE LOCATIONS" section). Reset alarm as
instructed below.

3 Beeps,

2 second pause,

Repeat

Silence Feature is activated by pressing and releasing the
Test/Silence button on the initiating alarm while in alarm
condition. Silence mode will last for 8-12 minutes.

Blinks On approx

every 2 seconds

Silent

(alarmed

previously)

Blinks On once

approx every

40-45 seconds (normal

operation mode) or

Blinks On once approx

every 10 seconds

(silence mode)

CONDITION OF ALARM AUDIBLE & VISUAL SIGNALS BEFORE SOLUTION / RECOMMENDATION

SOLUTION / RECOMMENDATION

HORN

RED LED

QUICK FIND

®

ALARM ORIGINATION: The QUICK FIND

®

feature will allow you to immediately locate the originating
alarm (once the alarm has stopped sounding). To initiate
QUICK FIND

®

, press the Test/Silence button on each alarm.

After releasing the button, the originating alarm will continue
to sound for 60 seconds. In a non-interconnected installation,
it is necessary to test each alarm to determine the originating
alarm. Reset the originating alarm.