Cut-out dimensions, 4 prepare site, 1115 series – U-Line 1175WC User Manual

Page 5: 29 series, Ada24 series, Warning, Important

background image

Prepare Site

3

4 Prepare Site

Your U-Line product has been designed for either free-standing or
built-in installation. When built-in, your unit does not require
additional air space for top, sides or rear. However, the front grille
must NOT be obstructed and clearance is required for an
electrical connection in the rear.

WARNING

Unit can NOT be installed behind a closed cabinet door.

WARNING

SHOCK HAZARD — Electrical Grounding Required.

• Never remove the round grounding prong from the

plug and never use a two-prong grounding adapter.

• Never use an extension cord to connect power to the

unit.

IMPORTANT

IMPORTANT

Electrical installation must observe all state and local
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a
qualified electrician.

The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A
power supply (normal household current). An individual, properly
grounded branch circuit or circuit breaker is recommended. GFCI
(ground fault circuit interrupter) is usually not required for fixed
location appliances and is not recommended for your unit because
a GFCI could be prone to nuisance tripping. However, be sure to
consult your local codes.

Cut-Out Dimensions

1175, 1075 & 75F Series

Follow the cut-out drawing. The 24-1/4" width allows 1/4" for ease
in installation and removal of the unit. 24" is the cabinet depth in
most installations.

1115 Series

Follow the cut-out drawing The 15-3/16" width allows 1/4" for
ease in installation and removal of the unit. 24" is the cabinet depth
in most installations.

29 Series

Follow the cut-out drawing. The 21-1/16" width allows 1/4" for
ease in installation and removal of the unit. 24" is the counter
depth in most installations. The unit is 23" deep including the door.

ADA24 Series

Follow the cut-out drawing The 24 1/4" width allows 1/4" for ease
in installation and removal of the unit. 24" is the cabinet depth in
most installations.

24”

1-1/2"

15-1/4"

7"

34-1/8"

to

35"

24"

Minimum

21-1/16"

Typical

Counter

Height

34-1/4"

to

35-1/8"

Cut-Out

Height

28-5/8"

to

28-7/8"

Filler Panel (Not Provided by U-Line) –

May Be Added Above or Below Unit

to Enclose for a Built-In Look

7"

1-1/2"

4"

7"

24"

24-1/4"

34-1/4"

to

35-1/8"

4"

7"

24"

24-1/4"

32”