beautypg.com

United States Stove Company DR6 User Manual

Page 7

background image

CAC

7

SHEET STEEL SUPPORTS

CHIMNEY SECTION

CHIMNEY
CONNECTOR

AIR SPACE
2 IN.

TWO VENTILATED AIR
CHANNELS EACH 1 INCH.
CONSTRUCTED OF
SHEET STEEL.

PART C
FIGURE 5

PART D
FIGURE 5

MINIMUM CLEARANCE
2 IN. ALL AROUND

CHIMNEY THIMBLE

1 IN. AIR SPACE TO
CHIMNEY LENGTH

MASONRY CHIMNEY CONSTRUCTED
TO NFPA 211

SHEET STEEL SUPPORTS
(24 GAUGE MIN. THICKNESS)

CHIMNEY FLUE

MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO
SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.

MASONRY CHIMNEY CONSTRUCTED
TO NFPA 211

SHEET STEEL SUPPORTS
(24 GAUGE MIN. THICKNESS)

CHIMNEY CONNECTOR
TO HEATER

MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO
SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.

MINIMUM 6 IN. GLASS
FIBER INSULATION ALL AROUND

24 GAUGE
VENTILATED THIMBLE WITH
TWO 1 INCH AIR CHANNELS

CHIMNEY THIMBLE

CHIMNEY FLUE

PART E - (Figure 5)
In addition to the methods shown by A, B, C, and D of Figure 5, a listed factory-built wall pass-through system
may be purchased and installed according to the instructions packaged with it to provide a safe method of
passing chimney connector through a combustible wall for a connection to a masonry chimney.

This manual is related to the following products: