Uniden BC340CRS User Manual
Page 22

22
Using the Scanner Memories
Once you fill out the above chart, follow these steps to enter or change a
frequency in a memory:
1. Press E/PGM to enter the program mode (the scanner turns on the
PGM icon).
2. If the current channel is not the one you want to program, enter the
memory number then press HOLD.
3. Enter the frequency including the decimal point, then press E/PGM.
4. To program the next memory, press
▲ or ▼ and repeat step 3. To
program a different memory, repeat from step 2.
5. To exit program mode, press HOLD or SCAN or change the scanner’s
mode.
Notes:
• Any frequency you program replaces the previous memory contents.
• If you enter a frequency you have already stored in a different
memory in Step 3, the scanner beeps and displays the channel
where you have previously stored the frequency. If you want to store
the frequency anyway, press E/PGM a second time in Step 3.
• To clear the contents of a memory, enter “0” in Step 3.
• Channels you program are automatically unlocked (see
“Locking/Unlocking Memories) and have Delay turned on (See
“Setting Channel Delay”).
Selecting a Memory
To select a single memory to monitor, press HOLD. The scanner turns on
the HOLD icon. Then, select a memory by pressing
▲ or ▼ to go to the
memory or input the memory number then press HOLD.
Bank 6
Bank 7
Bank 8
Bank 9
Bank 10
51
61
71
81
91
52
62
72
82
92
53
63
73
83
93
54
64
74
84
94
55
65
75
85
95
56
66
76
86
96
57
67
77
87
97
58
68
78
88
98
59
69
79
89
99
60
70
80
90
100
UB337ZH(BC340CRS) 1/13/06 4:20 PM Page 22