U-Line Plumbing Specfications

16

Drain Connection:

CAUTION

If your U-Line unit did not come with a factory installed

drain pump you must use a gravity style drain connection.

For assistance in determining if your unit has a pump

please contact U-Line. The floor drain must be large

enough to accommodate drainage from all attached

drains. Follow these guidelines when installing drain lines

to prevent water from flowing back into the ice maker

storage bin and/or potentially flowing onto the floor, which

may result in personal injury or property damage.

IMPORTANT

IMPORTANT

Drain can NOT be located directly below the unit. Unit
has a solid base that will not allow the unit to drain below
itself.

Gravity Drain:

A gravity drain may be used if:

• Drain line has at least a 1” drop per 48” of run (1/4” per foot).
• Drain line does not create traps and is vented per local code.

1. Cut the pre-installed drain tube to length.

2. Connect to your local plumbing per the local code.

3. If necessary, insulate drain line to prevent condensation.

4. Test the drain system per the test procedure under “Final

Installation” on page 17.

WARNING

Failure to connect water supply or drain line

connections properly can result in personal injury and

property damage. Gravity drain connections must be

routed downward from the rest of the unit at the rate

of 1/4” per foot.

Factory Installed Drain Pump

• If your drain line will run up to a stand pipe, disposal or spigot

assembly, or does not otherwise meet the requirements for a
gravity drain, you may have ordered the CLR2160 or
CLRCO2175 with a pre-installed U-Line P60 drain pump.

• If you need to install a P60 drain pump into your unit, see

Locally Installed Drain Pump on pg 17.

• See below for typical installations requiring a drain pump.

Normal

Proper Drain

With Trap

Poor Drainage, Water Will Back Up

With Trap and Vent

Proper Drain

Cold

Water

Hot

Water

Waste

Waste

Shut-Off

Valve

Stand Pipe
P60 Pump Required

Air Gap

(Optional Hook-Up)

Cold

Water

Hot

Water

Waste

Shut-Off

Valve

Disposal Assembly
P60 Pump Required

Waste

Cold

Water

Shut-Off

Valve

Hot

Water

Air Gap

(Optional Hook-Up)

Y-Branch Tailpiece
P60 Pump Required