Loop select 5. loop local 6. loop remote, Remote active led (telstra use only) – Telstrat NTU-45 User Manual
Page 2
DTE PORT 1
STATUS
TD
IN TEST
CONTROL
REMOTE
ACTIVE
RD
OPTICAL
INTERFACE
IN SERVICE
ALARM
IN TEST
LOS
DTE PORT 2
STATUS
TD
IN TEST
RD
DTE PORT 3
STATUS
TD
IN TEST
RD
DTE PORT 4
STATUS
TD
IN TEST
RD
LOOP
SELECT
LOOP
LOCAL
LOOP
REMOTE
DTE PORT 1
STATUS
TD
IN TEST
RD
OPTICAL
INTERFACE
IN SERVICE
ALARM
IN TEST
LOS
ST
I
LOOP
SELECT
LOOP
LOCAL
LOOP
REMOTE
DTE PORT 4
DTE PORT 3
DTE PORT 1
LAN
RX IN
TX OUT
ALARM
NC COM NO
DTE PORT 2
+
-
OPTICAL INTERFACE
USE COPPER
CONDUCTORS ONLY
48V
,0.5A
511 / 693
Laser Radiation
Avoid Exposure to Beam
Laser Class 1 Product
Complies with 21 CFR
1.
8.
9.
10.
11.
12.
13.
14.
Local Control Port
(Telstra use only)
VT100, EIA-232 Interface for local management
4. Loop Select
5. Loop Local
6. Loop Remote
48V DC power interface (Earth, Positive, Negative)
Slots to accomodate optional HSSI or V.35 DTE modules
The Loop Select button is used to select the port that is to be looped. It will cycle through
the four ports, causing the respective ports Test LED to flash.
When a loop is in place, pressing this button will turn the loop off.
When a port has been selected using the Loop Select button, pressing the Loop Local
button will initiate a loop on the selected port of the local NTU-45.
When a loop is in place, pressing this button will turn the loop off.
When a port has been selected using the Loop Select button, pressing the Loop Remote button
will initiate a loop on the selected port of the remote NTU-45.
When a loop is in place, pressing this button will turn the loop off.
In-built High Speed Serial Interface (HSSI)
Alarm Relay Contacts (Normally Closed, Common, Normally Open)
10BaseT LAN interface for remote management via MACS
Flat-SC Optical interface with separate Transmit and Receive fibres
Power Cord Strain Relief
T
DC Power erminal Block
DTE Ports 2, 3 and 4
DTE Port 1
Alarm Port
(Telstra use only)
Management Port
(Telstra use only)
Optical Interface Port
(Telstra use only)
Interfaces
NTU-45 Rear Panel
NTU-45 Front Panel
Front Panel Push Buttons
Front Panel LEDs
7. DTE Port LEDs (Customer Interfaces)
3. Optical Interface LEDs (Network Interface - Telstra Use Only)
Status (
Green
Yellow
or
Red
)
OFF indicates that there is no card installed
Flashing
GREEN
indicates that the interface is not configured for service
GREEN
indicates that the interface is ready to carry data.
YELLOW
indicates that the interface is ready, but cannot detect the
customer's equipment (DTE)
RED
indicates that there is a problem with the interface.
IN SERVICE (
Green
)
Indicates when the NTU-45 is powered on and functioning correctly .
2. Remote Active LED (Telstra use only)
Remote Active
(
Yellow
)
Indicates when the NTU-45 is being managed locally, or via a Telnet session
TEST (
Yellow
)
Indicates when a Loop or Bit Error Rate test is active on the Optical Interface.
ALARM (
Yellow
or
Red
)
YELLOW
indicates that there is a problem with the Remote NTU-45.
LOS (
Red
)
Indicates that the NTU-45 cannot detect any signal on the Optical Interface.
RED
indicates that the NTU-45 cannot align with the incoming signal.
In Test (
Yellow
)
Indicates when a Loop or Bit Error Rate test is active on the Interface.
During the process of activating a loop from the front panel push buttons,
this LED will Flash, indicating that it is selected but no Loop test exists.
TD (
Green
)
Indicates that the interface is transmitting data to the Newtork
RD (
Green
)
Indicates that the interface is receiving data from the Network
1
10
8
9
12
11
13
14
2
3
4 5 6
7