HDMI Compliance & Sink Characterization Using DTG5000 Series Data Timing Generator

Application Note

10

www.tektronix.com/signal_sources

10

Test Adapters

The approach using the DTGM32 and the AFG allows

for thorough compliance and pre compliance testing

with a much simpler setup than the AWG method.

This method was designed for pre/compliance testing

only since the maximum available jitter just meets

specification requirement. If testing is required above

the specification (as in characterization), then the

AWG method would be the recommended solution.

Reliable connections are key to maintaining precision

and signal integrity for all HDMI tests. There are two

types of test adapter sets available. For most of the

Sink tests devices, the plug-type adapters (TPA-P) set

and receptacle-type adapters (TPA-R) set are well

suited for making the primary connection to the

Device-under-test (DUT). Figure 9 shows a TPA-P

plug-type test adapter.

Figure 9.

TPA-P-TDR (013-A013-50) adapter.

Table 4.

DTG5000 Series files used by TDSHT3 in HDMI compliance tests.

DTG5000 Series Files Used in HDMI Compliance Test by TDSHT3

Test

Pix Clock

861B ID

Filename

Type

Image

Description

Sink

Minimum

25.2 MHz

480 p@60 Hz

640x480 p 60 Hz.dtg

8-5

Diff. Sensitivity

27.027 MHz

480 p@60 Hz

720x480 p 60 Hz.dtg

US

27.0 MHz

576 p@50 Hz

720x576 p 50 Hz.dtg

EU

Normal

74.25 MHz

1080 i@60 Hz

1920x1080 i 60 Hz.dtg

US

74.25 MHz

720 p@50 Hz

1280x720 p 50 Hz.dtg

EU

148.5 MHz

1080 p@60 Hz

1920x1080 p 60 Hz.dtg

Sink

Intra-Pair Skew

25.2 MHz

480 p@60 Hz

640x480 p 60 Hz IP.dtg

8-6

27.027 MHz

480 p@60 Hz

720x480 p 60 Hz IP.dtg

US

27.0 MHz

576 p@50 Hz

720x576 p 50 Hz IP.dtg

EU

Diff. Timing Offset

74.25 MHz

1080 i@60 Hz

1920x1080 i 60 Hz IP.dtg

US

74.25 MHz

720 p@50 Hz

1280x720 p 50 Hz IP.dtg

EU

148.5 MHz

1080 p@60 Hz

1920x1080 p 60 Hz IP.dtg

Gray RGB

Sink

Jitter Tolerance

25.2 MHz

480 p@60 Hz

640x480 p 60 Hz.dtg

8-7

27.027 MHz

480 p@60 Hz

720x480 p 60 Hz.dtg

US

27.0 MHz

576 p@50 Hz

720x576 p 50 Hz.dtg

EU

74.25 MHz

1080 i@60 Hz

1920x1080 i 60 Hz.dtg

US

Normal

74.25 MHz

720 p@50 Hz

1280x720 p 50 Hz.dtg

EU

148.5 MHz

1080 p@60 Hz

1920x1080 p 60 Hz.dtg

Cable

Cable Data

27.027 MHz

480 p@60 Hz

720x480 p 60 Hz CT.dtg

US

5-3

Eye Diagram

27.0 MHz

576 p@50 Hz

720x576 p 50 Hz CT.dtg

EU

74.25 MHz

1080 i@60 Hz

1920x1080 i 60 Hz CT.dtg

US

VH=3.3 V VL=2.9 V

74.25 MHz

720 p@50 Hz

1280x720 p 50 Hz CT.dtg

EU

148.5 MHz

1080 p@60 Hz

1920x1080 p 60 Hz CT.dtg

Most Likely Test Condition

Optional

Only If The Maximum Is 27MHz

27.027 MHz

27.0 MHz

27.027 MHz

27.0 MHz

74.25 MHz

74.25 MHz

148.5 MHz

27.027 MHz

27.0 MHz

74.25 MHz

74.25 MHz

148.5 MHz

27.027 MHz

27.0 MHz

74.25 MHz

74.25 MHz

148.5 MHz