THORENS TD158 User Manual
Page 8

TD 158_E
8
Mounting or exchanging a pick-up cartridge
Instead of the factory-supplied pick-up cartridge
any
other cartridge with standard half-inch mounting
holes and a weight between 3 and 10 grams can be
installed.
Unscrew the cartridge and carefully remove the
coloured signal leads from the cartridge pins with a
pair of tweezers. Screw the new cartridge onto the
head shell but do not tighten. Attach the leads to the
pins while observing the correct coding:
R
=
red
right channel
RG
=
green
right channel ground
L
=
white
left channel
LG
=
blue
left channel ground
Fig. 8
Electrical Safety
This device is in conformity with international safety regulations (IEC 65) and
EC regulations76/499/EWG.
ATTENTION!
During these mounting and adjustment procedures you must be very careful not to dam-
age the delicate stylus and cantilever by uncontrolled and brisk movements.