Troubleshooting, Contact us – Transition Networks CETTF10XX-105 User Manual
Page 6

CETTF10xx-105
10
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Troubleshooting
If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:
1.
Is the PWR LED illuminated?
NO
•
Is the media converter slide-in-module installed properly in the
chassis?
•
Is the power cord properly installed in the chassis and at the external
power source?
•
Does the external power source provide power?
•
Contact Tech Support: (800) 260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 2.
2.
Is the LKC LED illuminated?
NO
•
Check twisted-pair cables for proper connection.
•
Contact Tech Support: (800) 260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 3.
3.
Is the LKF LED illuminated?
NO
•
Check fiber cables for proper connection.
•
Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on other device.
•
Contact Tech Support: (800) 260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 4.
4.
Is the RXC LED flashing?
NO
•
If there is no activity on the 10Base-T port, proceed to step 5.
•
If there is activity on the 10Base-T port, disconnect and reconnect the
10Base-T cable to restart the initialization process.
•
Restart the workstation to restart the initialization process.
•
Contact Tech Support: (800) 260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 5.
5.
Is the RXF LED flashing?
NO
•
If there is no activity on the 10Base-FL port, continue below
•
If there is activity on the 10Base-FL port, disconnect and reconnect
the 10Base-FL cable to restart the initialization process.
•
Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on other device.
•
Restart the workstation to restart the initialization process.
•
Contact Tech Support: (800) 260-1312, Int’l: 00-1-952-941-7600.
YES
•
Contact Tech Support: (800) 260-1312, Int’l: 00-1-952-941-7600.
11
[email protected] -- Click the “Transition Now” link for a live Web chat.
Contact Us
Technical Support
Technical support is available 24 hours a day.
US and Canada:
1-800-260-1312
International:
00-1-952-941-7600
Transition Now
Chat live via the Web with Transition Networks Technical Support.
Log onto www.transition.com and click the Transition Now link.
Web-Based Seminars
Transition Networks provides seminars via live web-based training.
Log onto www.transition.com and click the Learning Center link.
Ask a question anytime by sending an e-mail to our technical support staff.
[email protected]
Address
Transition Networks
6475 City West Parkway
Minneapolis, MN 55344, U.S.A.
telephone:
952-941-7600
toll free:
800-526-9267
fax:
952-941-2322
Declaration of Conformity
Name of Mfg:
Transition Networks
6475 City West Parkway, Minneapolis MN 55344 U.S.A.
Model:
CETTF10xx-105 Series Media Converters
Part Number(s):
CETTF1011-105, CETTF1012-105, CETTF1013-105, CETTF1014-105,
CETTF1014-106, CETTF1015-105, CETTF1018-105, CETTF1022-105,
CETTF1027-105, CETTF1029-105, CETTF1029-106
Regulation:
EMC Directive 89/336/EEC
Purpose: To declare that the CETTF10xx-105 to which this declaration refers is
in conformity with the following standards.
CISPR 22:1993; EN 55022:1994+A1:1995+A2:1997; EN 55024:1998 Class A; FCC
Part 15 Subpart B; EN 61000-3-2:1995; EN61000-3-3:1995
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
April, 12 2006_____
Stephen Anderson, Vice-President of Engineering
Date